Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
AFS
Air flow meter
Air flow sensor
Airflow meter
Constriction rate-of-flow meter
Flow rate of a geotextile
Geotextile's transmissivity
Hydraulic transmissivity
In-plane permeability
In-plane transmissivity
MAF sensor
Mass air flow sensor
Mass airflow rate sensor
Mass airflow sensor
Meter minimum load
Meter minimum rating
Minimum load of a meter
Minimum rating of a meter
Planar permeability
Planar water flow
Produce a flow rate
Syphonage
Transitional flow rate of a meter
Transitional flow-rate
Transmissivity
Transmissivity of a geotextile

Vertaling van "Transitional flow rate a meter " (Engels → Frans) :

TERMINOLOGIE
transitional flow rate of a meter

débit de transition d'un compteur






minimum load of a meter [ minimum rating of a meter | meter minimum load | meter minimum rating ]

charge minimale d'un compteur


transmissivity [ hydraulic transmissivity | transmissivity of a geotextile | geotextile's transmissivity | flow rate of a geotextile | in-plane permeability | in-plane transmissivity | planar water flow | syphonage | planar permeability ]

transmissivité [ transmissivité hydraulique | transmissivité hydraulique d'un géotextile | transmissivité du géotextile ]




mass air flow sensor | mass airflow sensor | MAF sensor | mass airflow rate sensor | air flow meter | airflow meter | air flow sensor | AFS

débitmètre d'air massique


constriction rate-of-flow meter

débitmètre à étranglement
IN-CONTEXT TRANSLATIONS
The overall state of the economy remains an important factor in determining changes in the levels and flows to and from long-term unemployment, but there are also strong country-specific effects with some Member States (such as Finland, the Netherlands and Sweden) ensuring high transition rates back to employment in contrast to others, for instance Bulgaria, Greece and Slovakia.

L’état général de l’économie demeure un facteur déterminant en ce qui concerne le niveau du chômage de longue durée et le nombre de personnes qui entrent dans cette catégorie ou qui en sortent, mais on constate également des effets importants à l’échelon national, certains États membres (tels que la Finlande, les Pays-Bas et la Suède) parvenant à des taux élevés de transition du chômage vers l’emploi, contrairement à d’autres, comme la Bulgarie, la Grèce et la Slovaquie.


263. Where a meter is tested for acceptance limits of error or in-service limits of error using three consecutive tests conducted at any single rate of flow or at any flow rate of the same pattern that falls between its rated maximum flow and its rated minimum flow, the spread of the test results shall not exceed two fifths of the applicable limit of error for the meter.

263. Lors de l’essai d’un compteur portant sur les marges de tolérance à l’acceptation ou les marges de tolérance en service et consistant en trois essais consécutifs effectués à un débit unique ou à divers débits variant selon une séquence semblable comprise entre le débit minimum nominal et le débit maximum nominal du compteur, l’écart entre les résultats des essais ne doit pas excéder deux cinquièmes de la marge de tolérance applicable au compteur.


261. When a meter is tested for acceptance limits of error at any flow rate between its rated maximum flow and its rated minimum flow using a known test quantity of liquid set out in Column I of an item in the applicable table to sections 265 to 270, the meter is within the acceptance limits of error in respect of that quantity if the quantity registered by the meter does not differ from the known test quantity by an amount in excess of the amount set out in Column II of that item.

261. Lors de l’essai d’un compteur portant sur les marges de tolérance à l’acceptation, effectué à tout débit entre le débit maximal et le débit minimal et utilisant une quantité de liquide connue qui figure dans la colonne I d’un article du tableau correspondant des articles 265 à 270, le compteur est considéré conforme aux marges de tolérance en fonction de cette quantité lorsque la quantité enregistrée par le compteur ne s’écarte pas de la quantité de contrôle par un montant supérieur au montant qui figure dans la colonne II de cet article.


262. When a meter is tested for in-service limits of error at any flow rate between its rated maximum flow and its rated minimum flow using a known test quantity of liquid set out in Column I of an item in the applicable table to sections 265 to 270, the meter is within the in-service limits of error in respect of that quantity if the quantity registered by the meter does not differ from the known test quantity by an amount in excess of the amount set out in Column III of that item.

262. Lors de l’essai d’un compteur portant sur les marges de tolérance en service, effectué à tout débit entre le débit maximal et le débit minimal et utilisant une quantité de liquide connue qui figure dans la colonne I d’un article du tableau correspondant des articles 265 à 270, le compteur est considéré conforme aux marges de tolérance en fonction de cette quantité lorsque la quantité enregistrée par le compteur ne s’écarte pas de la quantité de contrôle par un montant supérieur au montant qui figure dans la colonne III de cet article.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
290. A meter shall be operated only at flow rates between the rated minimum and maximum flow rates marked on the name plate of the meter.

290. Un compteur ne doit fonctionner qu’à des débits variant entre le débit minimal et le débit maximal indiqués sur la plaque signalétique du compteur.


290. A meter shall be operated only at flow rates between the rated minimum and maximum flow rates marked on the name plate of the meter.

290. Un compteur ne doit fonctionner qu’à des débits variant entre le débit minimal et le débit maximal indiqués sur la plaque signalétique du compteur.


Accurate calibration of the flow meters relative to one another is required, since the relative magnitude of the two flow rates can lead to significant errors at higher dilution ratios.

Cette méthode exige un étalonnage précis des débitmètres l'un par rapport à l'autre, l'importance relative des deux débits pouvant entraîner des erreurs considérables lorsque les taux de dilution sont élevés.


9. Notes with satisfaction the general strengthening of Member States’ currencies outside the ERM II against the euro in 2004, which were particularly weighted by trade flows; welcomes this greater convergence of exchange rates and considers that these trends will smooth the future transition to the euro zone for non-euro-zone Member States;

9. constate avec satisfaction le renforcement général des monnaies des États membres qui n'adhèrent pas au mécanisme de change par rapport à l'euro en 2004, alors que les flux commerciaux ont pesé lourd; se félicite de cette convergence accrue des taux de change et considère que la tendance facilitera l'adhésion à la zone euro des États membres qui ne font pas partie de celle-ci;


Flow control valves and flow-meters are needed in order to obtain the flow-rates required for sampling.

Des régulateurs de débit et des débitmètres sont nécessaires pour obtenir les débits requis pour le prélèvement.


The temperature of the gas flow in the flow meter may not fluctuate more than ± 3 K, nor may the mass flow-rate fluctuate by more than ± 5 %.

La température du flux de gaz au niveau du débitmètre ne peut varier de plus ± 3 K et le débit massique de ± 5 %.