Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Volume of exhaust gas under standard conditions

Vertaling van "Volume exhaust gas under standard conditions " (Engels → Frans) :

TERMINOLOGIE
volume of exhaust gas under standard conditions

volume des effluents gazeux dans des conditions standard
IN-CONTEXT TRANSLATIONS
EUROPA - EU law and publications - EUR-Lex - EUR-Lex - 32008R0692 - EN - Commission Regulation (EC) No 692/2008 of 18 July 2008 implementing and amending Regulation (EC) No 715/2007 of the European Parliament and of the Council on type-approval of motor vehicles with respect to emissions from light passenger and commercial vehicles (Euro 5 and Euro 6) and on access to vehicle repair and maintenance information (Text with EEA relevance) - COMMISSION REGULATION - (EC) No 692/2008 // of 18 July 2008 // implementing and amending Regulation (EC) No 715/2007 of the European Parliament and of the Council on type-approval of motor vehicles with ...[+++]

EUROPA - EU law and publications - EUR-Lex - EUR-Lex - 32008R0692 - EN - Règlement (CE) n o 692/2008 de la Commission du 18 juillet 2008 portant application et modification du règlement (CE) n o 715/2007 du Parlement européen et du Conseil du 20 juin 2007 relatif à la réception des véhicules à moteur au regard des émissions des véhicules particuliers et utilitaires légers (Euro 5 et Euro 6) et aux informations sur la réparation et l’entretien des véhicules (Texte représentant de l’intérêt pour l’EEE) - RÈGLEMENT (CE) N - 692/2008 - DE LA COMMISSION // du 18 juillet 2008 - 715/2007 du Parlement européen et du Conseil du 20 juin 2007 relat ...[+++]


Supply standard for protected customers: Natural gas undertakings must secure supplies to protected customers under severe conditions: in the event of a seven day temperature peak and for at least 30 days of high demand, as well as in the case of an infrastructure disruption under normal winter conditions.

norme d’approvisionnement pour les clients protégés: les entreprises de gaz naturel sont tenues de garantir l’approvisionnement aux clients protégés dans des conditions rigoureuses, notamment en cas de températures extrêmes pendant une période de sept jours et pour au moins 30 jours de demande élevée, ainsi qu’en cas de défaillance des infrastructures dans des conditions hivernales normales.


mass of emitted substances per volume of waste gas under standard conditions (273,15 K, 101,3 kPa), after deduction of water vapour content, expressed in the units g/Nm3, mg/Nm3, μg/Nm3 or ng/Nm3; or

masse des substances émises par volume unitaire d'effluents gazeux dans les conditions standard (273,15 K, 101,3 kPa), après déduction de la teneur en vapeur d'eau, en g/Nm3, mg/Nm3, μg/Nm3 ou ng/Nm3


“Wobbe index (lower Wl or upper Wu)” means the ratio of the corresponding calorific value of a gas per unit volume and the square root of its relative density under the same reference conditions:

“indice de Wobbe (Wi inférieur ou Wu supérieur)”, le rapport du pouvoir calorifique correspondant d’un gaz par unité de volume par la racine carrée de sa densité relative dans les mêmes conditions de référence:


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(i)the possibility of introducing additional measures for suppliers to reduce by 2 % life cycle greenhouse gas emissions per unit of energy, in comparison with the fuel baseline standard referred to in Article 7a(5)(b), through the use of credits purchased through the Clean Development Mechanism of the Kyoto Protocol under the conditions set out in Directive 2003/87/EC, in order to assess further possible contributions for reaching a greenhouse gas reduction target of up to 10 % by 2020, as referred to in Article 7a(2)(c) of this Dire ...[+++]

i)la possibilité d’introduire des mesures supplémentaires afin que les fournisseurs réduisent de 2 % les émissions de gaz à effet de serre produites sur l’ensemble du cycle de vie par unité d’énergie, en comparaison avec les normes de base pour les carburants visées à l’article 7 bis, paragraphe 5, point b), grâce à l’utilisation de crédits acquis via le mécanisme pour un développement propre du protocole de Kyoto, dans les conditions prévues par la directive 2003/87/CE, afin d’examiner d’autres contributions éventuelles pour atteindr ...[+++]


the possibility of introducing additional measures for suppliers to reduce by 2 % life cycle greenhouse gas emissions per unit of energy, in comparison with the fuel baseline standard referred to in Article 7a(5)(b), through the use of credits purchased through the Clean Development Mechanism of the Kyoto Protocol under the conditions set out in Directive 2003/87/EC, in order to assess further possible contributions for reaching a greenhouse gas reduction target of up to 10 % by 2020, as referred to in Article 7a(2)(c) of this Directi ...[+++]

la possibilité d’introduire des mesures supplémentaires afin que les fournisseurs réduisent de 2 % les émissions de gaz à effet de serre produites sur l’ensemble du cycle de vie par unité d’énergie, en comparaison avec les normes de base pour les carburants visées à l’article 7 bis, paragraphe 5, point b), grâce à l’utilisation de crédits acquis via le mécanisme pour un développement propre du protocole de Kyoto, dans les conditions prévues par la directive 2003/87/CE, afin d’examiner d’autres contributions éventuelles pour atteindre ...[+++]


1.2.3. Correction of the diluted exhaust-gas volume to standard conditions. The diluted exhaust-gas volume is corrected by means of the following formula: >PIC FILE= "T0048874">

Le volume des gaz d'échappement dilués est ramené aux conditions normales par la formule suivante: >PIC FILE= "T0049125">


3.1.3.5. the positive displacement pump (PDP), used to transport a constant-volume flow of the air/exhaust-gas mixture ; the flow capacity of the pump must be large enough to eliminate water condensation in the system under all operating conditions which may occur during a test ; this can be generally ensured by using a positive displacement pump with a flow capacity: 3.1.3.5.1. - twice as high as the maximum flow of exhaust gas produced by accelerations of the driving cycle, or

3.1.3.5. une pompe volumétrique (PDP) produisant un débit volumique constant de mélange air/gaz d'échappement. La pompe doit avoir une capacité suffisante pour empêcher une condensation de l'eau dans l'appareillage dans toutes les conditions pouvant être rencontrées lors d'un essai. À cette fin on utilise en général une pompe volumétrique ayant une capacité: 3.1.3.5.1. double du débit maximal de gaz d'échappement engendré par les phases d'accélération du cycle d'essai


The system to be used is the constant volume sampler (CVS) system. This requires that the vehicle exhaust be continuously diluted with ambient air under controlled conditions. In the constant volume sampler concept of measuring two conditions must be satisfied : the total volume of the mixture of exhaust ...[+++]

Pour la mesure des émissions massiques par ce procédé, deux conditions doivent être remplies : le volume total du mélange de gaz d'échappement et d'air de dilution doit être mesuré et un échantillon proportionnel de ce volume doit être collecté pour analyse.


3.1.3.5. The positive displacement pump (PDP), used to transport a constant-volume flow of the air/exhaust-gas mixture ; the flow capacity of the pump must be large enough to eliminate water condensation in the system under all operating conditions which may occur during a test ; this can be generally ensured by using a positive displacement pump with a flow capacity: 3.1.3.5.1. - twice as high as the maximum flow of exhaust gas produced by accelerations of the driving cycle, or

3.1.3.5. une pompe volumétrique (PDP) servant à déplacer un débit volumique constant de mélange air/gaz d'échappement. La pompe doit avoir une capacité suffisante pour empêcher une condensation de l'eau dans l'appareillage dans toutes les conditions pouvant être rencontrées lors d'un essai. À cette fin, on utilise en général une pompe volumétrique ayant une capacité: 3.1.3.5.1. double du débit maximal de gaz d'échappement engendré par les phases d'accélération du cycle d'e ...[+++]




Anderen hebben gezocht naar : Volume exhaust gas under standard conditions     


datacenter (1): www.wordscope.be (v4.0.br)

'Volume exhaust gas under standard conditions' ->

Date index: 2023-03-15
w