Air water vapour
Atmospheric moisture content
Atmospheric water vapor content
Atmospheric water-vapor content
E'w
Nvi
Nvw
Water vapor content of the atmosphere
Water-vapor content of air
Water-vapour content of air

Vertaling van "Water-vapour content air " (Engels → Frans) :

TERMINOLOGIE
water vapor content of the atmosphere [ water-vapor content of air | water-vapour content of air | atmospheric water-vapor content | atmospheric water vapor content | atmospheric moisture content ]

teneur en vapeur d'eau de l'atmosphère [ teneur de l'air en vapeur d'eau | teneur en vapeur d'eau de l'air | contenu de l'air en vapeur d'eau | contenu de l'atmosphère en vapeur d'eau ]


mole fraction of saturation water vapour of moist air with respect to water

titre molaire de la vapeur d'eau saturante par rapport à l'eau


mole fraction of saturation water vapour of moist air with respect to water | Nvw

titre molaire de la vapeur d'eau saturante par rapport à l'eau | Nvw


mole fraction of saturation water vapour of moist air with respect to ice | Nvi

titre molaire de la vapeur d'eau saturante par rapport à la glace | Nvi




saturation vapour pressure of moist air with respect to water | e'w

tension de vapeur saturante de l'air humide par rapport à l'eau | e'w
IN-CONTEXT TRANSLATIONS
All emission limit values set out in this Annex are defined at a temperature of 273,15 K, a pressure of 101,3 kPa and after correction for the water vapour content of the waste gases and at a standardised O2 content of 6 % for medium combustion plants using solid fuels, 3 % for medium combustion plants, other than engines and gas turbines, using liquid and gaseous fuels and 15 % for engines and gas turbines.

Toutes les valeurs limites d'émission figurant dans la présente annexe sont définies pour une température de 273,15 K, une pression de 101,3 kPa et après correction en fonction de la teneur en vapeur d'eau des gaz résiduaires, et pour une teneur normalisée en O2 de 6 % dans le cas des installations de combustion moyennes utilisant des combustibles solides, de 3 % dans le cas des installations de combustion moyennes, autres que les moteurs et turbines à gaz, qui utilisent des combustibles liquides et gazeux, et de 15 % dans le cas des moteurs et des turbines à gaz.


All emission limit values set out in this Annex are defined at a temperature of 273,15 K, a pressure of 101,3 kPa and after correction for the water vapour content of the waste gases and at a standardised O2 content of 6 % for medium combustion plants using solid fuels, 3 % for medium combustion plants, other than engines and gas turbines, using liquid and gaseous fuels and 15 % for engines and gas turbines.

Toutes les valeurs limites d'émission figurant dans la présente annexe sont définies pour une température de 273,15 K, une pression de 101,3 kPa et après correction en fonction de la teneur en vapeur d'eau des gaz résiduaires, et pour une teneur normalisée en O2 de 6 % dans le cas des installations de combustion moyennes utilisant des combustibles solides, de 3 % dans le cas des installations de combustion moyennes, autres que les moteurs et turbines à gaz, qui utilisent des combustibles liquides et gazeux, et de 15 % dans le cas des moteurs et des turbines à gaz.


1. All emission limit values shall be calculated at a temperature of 273,15 K, a pressure of 101,3 kPa and after correction for the water vapour content of the waste gases and at a standardised O2 content of 6 % for solid fuels, 3 % for boilers using liquid and gaseous fuels and 15 % for gas turbines and gas engines.

1. Toutes les valeurs limites d'émission sont calculées à une température de 273,15 K, à une pression de 101,3 kPa et après correction en fonction de la teneur en vapeur d'eau des gaz résiduaires, et pour une teneur normalisée en O2 de 6 % dans le cas des combustibles solides, de 3 % dans le cas des chaudières utilisant des combustibles liquides et gazeux et de 15 % dans le cas des turbines à gaz et des moteurs à gaz.


7. The continuous measurements carried out in accordance with point 1 shall include the measurement of the oxygen content, temperature, pressure and water vapour content of the waste gases.

7. Les mesures en continu effectuées conformément au point 1 incluent la détermination de la teneur en oxygène, de la température, de la pression et de la teneur en vapeur d'eau des gaz résiduaires.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
‘air conditioner’ means a device capable of cooling or heating, or both, indoor air, using a vapour compression cycle driven by an electric compressor, including air conditioners that provide additional functionalities such as dehumidification, air-purification, ventilation or supplemental air-heating by means of electric resistance heating and appliances that may use water (either condensate water that is formed on the evaporator side or externally added water) for evaporation on the condensor, provided that the device is also able t ...[+++]

«climatiseur», un appareil capable de refroidir et/ou de chauffer l'air intérieur par un cycle à compression de vapeur généré par un compresseur électrique, notamment, d'une part, les climatiseurs dotés de fonctions additionnelles, telles que la déshumidification, la purification, la ventilation ou le chauffage par résistance électrique d'appoint et, d'autre part, les appareils qui peuvent utiliser de l'eau (soit l'eau issue de la condensation au niveau de l'évaporateur soit de l'eau provenant d'une source externe) pour évaporation au niveau du condenseur, à condition que l'appareil soit aussi capable de fonctionner sans source externe d ...[+++]


I would point out that a two-degree increase in air temperature, from 20 to 22°C, means a 12% increase in the water vapour content of the atmosphere and hence in the amount of energy in the atmosphere, as we have unfortunately seen confirmed in hurricane Katrina.

Je voudrais attirer votre attention sur le fait qu’une augmentation de la température de l’air de deux degrés, de 20 à 22 °C, entraîne une hausse de 12% de la teneur en vapeur d’eau et, partant, de la quantité d’énergie dans l’atmosphère, fait malheureusement confirmé par l’ouragan Katrina.


Carbon dioxide is produced by fish during respiration and dissolves in water to form carbonic acid, thus lowering the pH. Accumulation of carbon dioxide can be a problem at a high stocking density if pure oxygen is used instead of air to maintain the oxygen content in the water.

Le dioxyde de carbone est produit par les poissons pendant la respiration et se dissout dans l'eau pour former de l'acide carbonique, en réduisant le niveau du pH. L'accumulation de dioxyde de carbone peut poser un problème en présence d'une densité de peuplement élevée si on utilise de l'oxygène à l'état pur, au lieu de l'air, pour maintenir le niveau d'oxygène dans l'eau.


5. The continuous measurements carried out in compliance with paragraph 2 shall include the relevant process operation parameters of oxygen content, temperature, pressure and water vapour content.

5. Les mesures en continu effectuées conformément au paragraphe 2 incluent les paramètres d'exploitation pertinents que sont la teneur en oxygène, la température, la pression et la teneur en vapeur d'eau.


(2) "waste gases" means gaseous discharges containing solid, liquid or gaseous emissions; their volumetric flow rates shall be expressed in cubic metres per hour at standard temperature (273 K) and pressure (101,3 kPa) after correction for the water vapour content, hereinafter referred to as (Nm3/h).

2) "gaz résiduaires", des rejets gazeux contenant des émissions solides, liquides ou gazeuses; leur débit volumétrique est exprimé en mètres cubes par heure rapportés à des conditions normalisées de température (273 K) et de pression (101,3 kPa) après déduction de la teneur en vapeur d'eau, ci-après dénommé "Nm3/h".


The continuous measurement of the water vapour content of the exhaust gases shall not be necessary, provided that the sampled exhaust gas is dried before the emissions are analysed.

La mesure en continu de la teneur en vapeur d'eau des gaz de combustion n'est pas nécessaire lorsque les gaz de combustion échantillonnés sont séchés avant analyse des émissions.