Light Measurement Protocols: When light measurements, such as illuminance and luminance, need to be made, a LMD shall be used with the computer monitor located in dark room conditions. The LMD shall be used to make measurements at the centre of, and perpendicular to the computer monitor screen (Reference VESA FPDM Standard 2.0, Appendi
x A115). The screen surface area to be measured shall cover at least 500 pixels, unless this exceeds the equivalent of a rectangular area with sides of lengths equal to 10 % of the visible screen height and width (in which case this latter limit
...[+++] applies). However, in no case may the illuminated area be smaller than the area the LMD is measuring (Reference VESA FPDM Standard 2.0, Section 301-2H). Lichtmetingsp
rotocollen: Wanneer lichtmetingen moeten worden
verricht, zoals van illuminantie en luminantie, wordt een LMD gebruikt en moet de computermonitor zich in een d
onkerekamersituatie bevinden. De LMD wordt gebruikt om metingen te doen in het midden van en loodrecht op het beeldscherm (Referentie VESA FPDM Norm 2.0, Bijlage A115). Er wordt gemeten op een schermoppervlakte van minstens 500 pixels, tenzij deze oppervlakte groter is dan het equivalent van een rechthoe
...[+++]k met zijden gelijk aan 10 % van de zichtbare schermhoogte en -breedte (in dat geval geldt het laatstgenoemde). In geen geval mag het verlichte oppervlak echter kleiner zijn dat het oppervlak waarop de LMD meet (Referentie VESA FPDM Norm 2.0, punt 301-2H).