Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
CC flash point test
Closed cup flash point test
OC flash point test
Open cup flash point test
PM flash-point test
Pensky-Martens flash-point test
Pensky-Martens test
Thermometer for flash point testing

Vertaling van "CC flash point test " (Engels → Frans) :

TERMINOLOGIE
closed cup flash point test | CC flash point test

test en coupelle fermée


Pensky-Martens flash-point test [ PM flash-point test | Pensky-Martens test ]

essai Pensky-Martens


open cup flash point test | OC flash point test

test en coupelle ouverte


thermometer for flash point testing

thermomètre pour détermination du point d'éclair
IN-CONTEXT TRANSLATIONS
(a) a liquid, other than a liquid referred to in paragraph (c) or (d), having a viscosity of less than 5.8 mm /s (45 Saybolt Universal Seconds) at 37.8°C (100°F) is the Standard Test Method for Flash Point by Tag Closed Tester ASTM D56-82, dated August 27, 1982, or the appropriate test in the Standard Test Methods for Flash Point by Setaflash Closed Tester, ASTM D3828-81, dated August 28, 1981;

a) dans le cas d’un liquide dont la viscosité à 37,8 °C (100 °F) est inférieure à 5,8 mm /s (45 secondes universelles Saybolt) et qui n’est pas visé aux alinéas c) ou d), la méthode décrite dans la norme D56-82 de l’ASTM intitulée Standard Test Method for Flash Point by Tag Closed Tester, en date du 27 août 1982, ou la méthode décrite dans la norme D3828-81 de l’ASTM intitulée Standard Test Methods for Flash Point by Setaflash Closed Tester, en date du 28 août 1981;


(d) a paint, enamel, lacquer, varnish or similar liquid that has a flash point between 0°C (32°F) and 110°C (230°F) and a viscosity of less than 15 000 mm /s at 25°C (77°F) determined in accordance with the Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and the Calculation of Dynamic Viscosity), ASTM D445-83, dated October 28, 1983, is the appropriate test in the Standard Test Methods for Flash Point of Liquids by Setaflash Closed-Cup Apparatus, ASTM D3278-82, ...[+++]

d) dans le cas de peinture, d’émail, de laque, de vernis ou d’un liquide similaire dont le point d’éclair se situe entre 0° C (32 °F) et 110 °C (230 °F) et dont la viscosité à 25 °C (77 °F) est inférieure à 15 000 mm /s, déterminée selon la méthode D445-83 de l’ASTM intitulée Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and the Calculation of Dynamic Viscosity), en date du 28 octobre 1983, la méthode décrite dans la norme D3278-82 de l’ASTM intitulée Standard Test Methods for ...[+++]


(b) a liquid, other than a liquid referred to in paragraph (c) or (d), having a viscosity of 5.8 mm /s (45 Saybolt Universal Seconds) or more at 37.8°C (100°F), is the appropriate test in the Standard Test Methods for Flash Point by Pensky-Martens Closed Tester, ASTM D93-80, dated August 29, 1980;

b) dans le cas d’un liquide dont la viscosité à 37,8 °C (100 °F) est égale ou supérieure à 5,8 mm /s (45 secondes universelles Saybolt) et qui n’est pas visé aux alinéas c) ou d), la méthode décrite dans la norme D93-80 de l’ASTM intitulée Standard Test Methods for Flash Point by Pensky-Martens Closed Tester, en date du 29 août 1980;


(c) an aviation turbine fuel is the appropriate test in the Standard Test Methods for Flash Point by Setaflash Closed Tester, ASTM D3828-81, dated August 28, 1981; and

c) dans le cas d’un carburant d’aviation pour moteur à turbine, la méthode décrite dans la norme D3828-81 de l’ASTM intitulée Standard Test Methods for Flash Point by Setaflash Closed Tester, en date du 28 août 1981;


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
50. A flammable product in the form of a liquid must be tested for its flash point in accordance with the following standards:

50. Tout produit inflammable sous forme liquide doit être mis à l’essai afin de déterminer son point d’éclair conformément aux normes suivantes :


According to paragraph 2.6.4.5 in Annex I to Regulation (EC) No 1272/2008, liquids with a flash point of more than 35 °C need not be classified in Category 3 if negative results have been obtained in the sustained combustibility test L.2, Part III, section 32 of the UN Manual of Tests and Criteria.

Conformément au paragraphe 2.6.4.5 de l'annexe I du règlement (CE) no 1272/2008, il n'est pas nécessaire de classer les liquides ayant un point d'éclair supérieur à 35 °C dans la catégorie 3 si l'épreuve de combustion entretenue du point L.2, partie III, section 32, du Manuel d'épreuves et de critères des Nations unies a donné des résultats négatifs.


2.6.4.5 Liquids with a flash point of more than 35 °C and not more than 60 °C need not be classified in Category 3 if negative results have been obtained in the sustained combustibility test L.2, Part III, section 32 of the UN RTDG, Manual of Tests and Criteria’.

2.6.4.5. Il n’est pas nécessaire de classer les liquides ayant un point d’éclair supérieur à 35 °C et ne dépassant pas 60 °C dans la catégorie 3 si des résultats négatifs ont été obtenus lors de l’essai de combustion entretenue L.2, troisième partie, section 32 des Recommandations relatives au transport des marchandises dangereuses des Nations unies, Manuel d’épreuves et de critères».


22. Notes that the IEA’s World Energy Outlook 2011 includes a ‘lower-nuclear’ case according to which the projected increase in worldwide CO2 emissions from the power sector would be substantially higher in the medium term due to an increased use of fossil fuels; reiterates that the decision by some Member States to shut down some existing nuclear reactors must not serve as justification to reduce the level of ambition in their current climate policies; states that, according to the IEA, achieving the 2°C goal would require faster development and deployment of CCS technologies in both coal and gas-fired power plants; points out, however, that ...[+++]

22. relève que les perspectives énergétiques mondiales 2011 de l'AIE comportent un scénario "nucléaire bas", selon lequel l'augmentation projetée des émissions mondiales de CO2 dues au secteur de l'électricité serait beaucoup plus forte à moyen terme du fait d'une utilisation accrue des combustibles fossiles; réaffirme que la décision de certains États membres de fermer certains réacteurs nucléaires ne doit pas servir à justifier une révision à la baisse du niveau d'ambition de leurs politiques climatiques actuelles; relève que, selon l'AIE, pour atteindre l'objectif des 2°C, il faudrait accélérer le développement et le déploiement des ...[+++]


76. Draws attention to the fact that the current 20 % target is based on the contribution made by nuclear power to the energy mix in number of Member States; notes that the IEA's World Energy Outlook 2011 includes a ‘lower-nuclear’ case according to which the projected increase in worldwide CO2 emissions from the power sector would be substantially higher in the medium term due to an increased use of fossil fuels; reiterates that the decision by some Member States to shut down some existing nuclear reactors must not serve to justify reducing the level of ambition of their current climate policies; points out that, according to the IEA ...[+++]

76. attire l'attention sur le fait que l'objectif actuel de 20 % repose sur la contribution de l'énergie nucléaire à la palette énergétique de certains États membres; relève que les perspectives énergétiques mondiales 2011 de l'AIE comportent un scénario «nucléaire bas», selon lequel l'augmentation projetée des émissions mondiales de CO2 dues au secteur de l'électricité serait beaucoup plus forte à moyen terme du fait d'une utilisation accrue des combustibles fossiles; réaffirme que la décision de certains États membres de fermer certains réacteurs nucléaires ne doit pas servir à justifier une révision à la baisse du niveau d'ambition de leurs politiques climatiques actuelles; relève que, selon l'AIE, pour atteindre l'objectif des 2°C, i ...[+++]


77. Draws attention to the fact that the current 20 % target is based on the contribution made by nuclear power to the energy mix in number of Member States; notes that the IEA’s World Energy Outlook 2011 includes a ‘lower-nuclear’ case according to which the projected increase in worldwide CO2 emissions from the power sector would be substantially higher in the medium term due to an increased use of fossil fuels; reiterates that the decision by some Member States to shut down some existing nuclear reactors must not serve to justify reducing the level of ambition of their current climate policies; points out that, according to the IEA ...[+++]

77. attire l'attention sur le fait que l'objectif actuel de 20 % repose sur la contribution de l'énergie nucléaire à la palette énergétique de certains États membres; relève que les perspectives énergétiques mondiales 2011 de l'AIE comportent un scénario "nucléaire bas", selon lequel l'augmentation projetée des émissions mondiales de CO2 dues au secteur de l'électricité serait beaucoup plus forte à moyen terme du fait d'une utilisation accrue des combustibles fossiles; réaffirme que la décision de certains États membres de fermer certains réacteurs nucléaires ne doit pas servir à justifier une révision à la baisse du niveau d'ambition de leurs politiques climatiques actuelles; relève que, selon l'AIE, pour atteindre l'objectif des 2°C, i ...[+++]




datacenter (1): www.wordscope.be (v4.0.br)

'CC flash point test' ->

Date index: 2021-03-29
w