In this case, the instan
taneous mass of the diluted exhaust gas shall be calculated as follows: M TOTW ,i = 1,293 x V0 x NP,i x (pB - p1 ) x 273 / (101,3 x T) where NP,i = t
otal revolutions of pump per time interval CFV-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust gas is kept within ± 11K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x t x Kv x pA / T where M TOTW = mass of the diluted exhaust gas on wet basis over the cycle t = cycle time (s) KV = cali
...[+++]bration coefficient of the critical flow venturi for standard conditions, pA = absolute pressure at venturi inlet (kPa) T = absolute temperature at venturi inlet (K) If a system with flow compensation is used (i.e. without heat exchanger), the instantaneous mass emissions shall be calculated and integrated over the cycle.Dans ce cas, la masse instantanée d
e gaz d'échappement dilués est calculée comme suit: M TOTW ,i = 1,293 x V0 x NP,i x (pB - p1 ) x 273 / (101,3 x T) où: NP,i = nombre t
otal de tours de la pompe par intervalle de temps Système CFV-CVS Le débit massique durant le cycle est calculé comme suit si la température des gaz d'échappement dilués est maintenue dans une limite de ± 11 K durant tout le cycle à l'aide d'un échangeur de chaleur: M TOTW = 1,293 x t x Kv x pA / T où: MTOTW = masse de gaz d'échappement dilués en conditions humides dur
...[+++]ant le cycle (en kg) t = temps de cycle (en s) KV = coefficient d'étalonnage du venturi à écoulement critique dans des conditions normalisées pA = pression absolue à l'entrée du venturi (en kPa) T = température absolue à l'entrée du venturi (en K) Si un système à compensation de débit est utilisé (c'est-à-dire sans échangeur de chaleur), les émissions massiques instantanées doivent être déterminées et intégrées sur la durée du cycle.