Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Fire pump carried by men

Traduction de «Fire pump carried by men » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous


TRADUCTIONS EN CONTEXTE
(4) In every Class B ship over 22.9 m in length carrying more than 12 passengers, at least one of the power fire pumps shall be fitted with an automatic control whereby full pressure will be maintained on the fire mains at all times while passengers are on board excepting that where piping is liable to frost damage such piping may be maintained in a drained condition provided the shut-off valve and drainage cocks are located in a readily accessible location with a pressure gauge being installe ...[+++]

(4) Sur tout navire de la classe B long de plus de 22,9 m et transportant plus de 12 passagers, au moins l’une des pompes d’incendie mécaniques aura une commande automatique permettant de maintenir en tout temps la pression dans les collecteurs pendant que des passagers seront à bord, mais si le gel risque d’endommager certains tronçons des conduites, ces tronçons peuvent être vidangés et demeurer dans cet état, à condition que la soupape d’arrêt et les robinets de vidange soient situés en un endroit facilement accessible et qu’un man ...[+++]


(5) Dock trials and sea trials of a fishing vessel shall be held in the presence of an inspector, at which time the speed of the vessel, in knots, shall be estimated, the bilge and fire pumps and the steering and stopping powers of the vessel shall be tested, the launching arrangements for the life boats, boats, dories or skiffs shall be carried out, and any further tests shall be carried out that the inspector considers necessary to satisfy himself that the vessel is safe and suitable for the ...[+++]

(5) Les essais au point fixe et les essais à la mer d’un bateau de pêche seront exécutés en présence de l’inspecteur et, à cette occasion, les pompes de cale et les pompes d’incendie seront essayées, la vitesse en noeuds sera estimée, l’appareil à gouverner et la puissance de stoppage du navire seront mis à l’épreuve, les dispositifs de mise à l’eau des embarcations de sauvetage ou autres, des doris ou des esquifs seront essayés, et il sera effectué tous autres essais que l’inspecteur jugera nécessaires pour avoir la certitude que le ...[+++]


Conscious of the need to maintain his position of observation of the opposing forces, he moved his armoured vehicle while preparing to return fire to safeguard his men and carry out his task.

Conscient du besoin de maintenir ce poste d'observation des belligérants, il plaça son véhicule blindé devant ses hommes afin de les protéger et de pouvoir riposter et de poursuivre sa mission.


26. Where the superstructure of a passenger ship carrying more than 12 passengers is constructed of aluminum alloy and Method II of fire protection is employed in accordance with the Hull Construction Regulations, the whole unit including the sprinkler pump, tank and air compressor shall be situated, to the satisfaction of the Board, in a position reasonably remote from the boilers and machinery spaces, and, if the feeders from the ...[+++]

26. Si les superstructures d’un navire à passagers qui transporte plus de 12 passagers sont en alliage d’aluminium et que la méthode II de protection contre l’incendie est employée conformément aux prescriptions du Règlement sur la construction des coques, l’ensemble du système de diffuseurs, comprenant la pompe qui alimente le dispositif, le réservoir et le compresseur d’air occupera un emplacement agréé par le Bureau et convenablement éloigné des chaufferies et des locaux de machines et, si les canalisations qui relient la génératri ...[+++]


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
97 (1) Every Class K ship that carries oil cargo in bulk shall be provided with appliances whereby smothering gas, steam or foam can be rapidly conveyed by a permanent piping system into the cargo pump room and into all cargo spaces, or, in lieu thereof, shall be provided with foam fire extinguishers in accordance with the following table, or equivalent fire extinguishers as set forth in Schedule IV:

97 (1) Tout navire de la classe K porteur d’huile de chargement en vrac aura des appareils permettant d’envoyer rapidement, par un tuyautage permanent, du gaz inerte, de la vapeur d’eau ou de la mousse dans la chambre des pompes de chargement et dans tous les locaux à marchandises ou, à défaut, des extincteurs à mousse conformément au tableau suivant, ou des extincteurs équivalents tel qu’il est indiqué à l’annexe IV :


The first plea is therefore based on the fact that the Republic of Poland has not to date forwarded to the Commission the names of the certification bodies for personnel and companies which carry out checks for leakage, installation, servicing or maintenance of stationary refrigeration equipment, air-conditioning equipment, heat-pump equipment, fire-protection systems and fire extinguishers, and which perform activities in connection with the recovery of those fluorinated greenhouse gases; nor has it forwarded to the Commission the t ...[+++]

Le premier moyen invoqué à l’appui du recours est donc tiré du fait que la République de Pologne n’a pas à ce jour notifié à la Commission les noms des organismes de certification du personnel et des entreprises effectuant les contrôles d’étanchéité, l'installation, la maintenance ou l'entretien des équipements fixes de réfrigération, de climatisation et de pompes à chaleur, des systèmes de protection contre l’incendie et des extincteurs, et la récupér ...[+++]




D'autres ont cherché : fire pump carried by men     Fire pump carried by men     


datacenter (1): www.wordscope.be (v4.0.br)

'Fire pump carried by men' ->

Date index: 2024-11-10
w