Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Accelerometer valve
Accelerometer-controlled servo valve
Automatic shut-off valve
Bang-bang servo valve
Control valve
Electrohydraulic flow control servo valve
Flow control hydraulic servo valve
Flow control hydraulic servo-valve
Flow control unit
Flow control valve
Flow controlled servo valve
Flow gain-servo valve
ISC
Idle speed control
Idle speed control motor
Idle speed control servo
Idle speed control valve
Maximum flow control valve

Vertaling van "Flow controlled servo valve " (Engels → Frans) :

TERMINOLOGIE
flow controlled servo valve

servo-distributeur à contrôle de débit


electrohydraulic flow control servo valve

servo-valve électrohydraulique de régulation de débit


accelerometer valve [ accelerometer-controlled servo valve | bang-bang servo valve ]

valve à accéléromètre




flow control hydraulic servo-valve

servo-distributeur hydraulique de débit


flow control hydraulic servo valve

servo-distributeur hydraulique de débit




idle speed control motor | ISC | idle speed control | idle speed control servo | idle speed control valve

moteur de commande de ralenti | moteur linéaire de commande de ralenti


flow control valve | flow control unit

régulateur de débit


automatic shut-off valve | maximum flow control valve

soupape de fermeture | limiteur de débit maximal
IN-CONTEXT TRANSLATIONS
280. Sealed flow control valves or other means shall be installed with a meter to limit the flow through the meter to its rated maximum flow.

280. Des soupapes scellées de contrôle du débit ou d’autres dispositifs scellés doivent être installés sur un compteur pour limiter le débit du compteur à son plein régime.


(c) no valves, pumps, flow-control valves or other equipment that may alter the temperature of the liquid are located between the meter chamber and the sensor.

c) qu'il n'y ait pas de soupape, de pompe, de valve de réglage du débit ou d'autre pièce d'équipement susceptible de faire varier la température du liquide qui soit installée entre la chambre de mesure du compteur et le capteur.


(6) Hose and hose connections located on the low pressure side of flow control or pressure reducing valves or devices, discharging to atmospheric pressure, shall be designed for a minimum working pressure of 60 psig.

(6) Les tuyaux flexibles et leurs raccords situés du côté basse pression des soupapes ou dispositifs régulateurs de débit ou monodétendeurs devront être étudiés de façon à pouvoir supporter une pression de régime d’au moins 60 livres par pouce carré au manomètre.


(3) An excess flow valve or other automatic device as prescribed in subsection (1) is not required for withdrawal connections of tanks with a water capacity of 1,500 Imperial gallons or less if the connection is protected by a controlling orifice not exceeding 5/16 inch diameter on vapour withdrawal and not exceeding 1/8 inch diameter on liquid withdrawal, a manually operated shut-off valve and pressure-reducing regulator, all of which are assembled to the connection as prescribed in 2.2(d), D ...[+++]

(3) Les soupapes d’excès de débit ou autres dispositifs automatiques prescrits au paragraphe (1) ne sont pas requis dans le cas des raccords d’extraction des réservoirs dont la capacité en eau est de 1 500 gallons impériaux ou moins, si le raccord est protégé par un orifice de contrôle dont le diamètre n’excède pas 5/16 de pouce pour l’extraction de gaz ni 1/8 de pouce pour l’extraction de liquide, par une soupape d’arrêt à commande manuelle et par un régulateur manodétendeur, tous ces dispositifs étant montés sur le raccordement comme il est prescrit à l’article 2.2(d), division II de l’édition de 1958 de la brochure n 58 de l’Associati ...[+++]


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(4) An excess flow valve or other automatic device as prescribed in subsection (1) is not required for withdrawal connections of unrefrigerated tanks with a water capacity not exceeding 1,500 Imperial gallons, if the connection is protected by a controlling orifice not exceeding 5/16 inch diameter for vapour withdrawal and 1/8 inch diameter for liquid withdrawal, a manually operated shut-off valve, and a pressure-reducing regulator, all of which shall be assembled to the connection as prescrib ...[+++]

(4) Les soupapes d’excès de débit ou autres dispositifs automatiques prescrits au paragraphe (1) ne sont pas requis dans le cas des raccords d’extraction des réservoirs non réfrigérés dont la capacité en eau est de 1 500 gallons impériaux ou moins, si le raccord est protégé par un orifice de contrôle dont le diamètre n’excède pas 5/16 de pouce pour l’extraction de gaz ni 1/8 de pouce pour l’extraction de liquide, par une soupape d’arrêt à commande manuelle et par un régulateur manodétendeur, tous ces dispositifs étant montés sur le raccord comme il est prescrit à l’article 2.2(d), Division II de l’édition de 1958 de la brochure n 58 de l ...[+++]


c. Flight control servo valves designed or modified for the systems specified in 7A116.a. or 7A116.b., and designed or modified to operate in a vibration environment of more than 10 g rms over the entire range between 20 Hz and 2 kHz.

c. servovalves de contrôle du vol conçues ou modifiées pour les systèmes visés aux alinéas 7A116.a. ou 7A116.b., et conçus ou modifiés pour fonctionner dans un environnement de vibrations de plus de 10 g eff (rms) sur l'ensemble de la plage de fréquence entre 20 Hz et 2 kHz.


a. Servo valves designed for flow rates of 24 litres per minute or greater, at an absolute pressure of 7 MPa or greater, that have an actuator response time of less than 100 ms;

a. servovalves conçues pour des débits de 24 l/min ou plus, sous une pression absolue égale ou supérieure à 7 MPa, ayant un temps de réponse de l'actionneur inférieur à 100 ms;


7A116 Flight control systems and servo valves, as follows; designed or modified for use in space launch vehicles specified in 9A004 or sounding rockets specified in 9A104.

7A116 Systèmes de commande de vol et servovalves, conçus ou modifiés pour être utilisés dans les lanceurs et véhicules spatiaux visés au paragraphe 9A004 ou dans les fusées sondes visées au paragraphe 9A104, comme suit:


The proportional sample is achieved by sampling with pump, flow-meter and flow control valve at a constant flow-rate.

On obtient l'échantillon proportionnel en opérant un prélèvement à débit constant, au moyen d'une pompe, d'un débitmètre et d'une vanne de réglage du débit.


Flow control valves and flow-meters are needed in order to obtain the flow-rates required for sampling.

Des régulateurs de débit et des débitmètres sont nécessaires pour obtenir les débits requis pour le prélèvement.