Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Engine room
Evaporator room
Fire room
Fuel oil burning
Galley
Gas-oil fired boiler
Laundry
Liquid fuel boiler
Loading
Machinery
Mazout boiler
Oil boiler
Oil fired arch
Oil fired evaporator arch
Oil firing
Oil firing boiler
Oil fuel firing
Oil furnace
Oil-fired boiler
Oil-fired evaporator
Oil-firing boiler
Oil-fuel boiler

Vertaling van "Oil-firing boiler " (Engels → Frans) :

TERMINOLOGIE


oil-fired boiler [ oil boiler | oil-fuel boiler | mazout boiler | oil furnace ]

chaudière à mazout [ chaudière au mazout | fournaise à l'huile ]


liquid fuel boiler | oil-fired boiler

chaudière à combustible liquide | chaudière à mazout | générateur à mazout




gas-oil fired boiler

chaudière au gazole [ chaudière au gasoil | chaudière au gas-oil ]






oil-fired evaporator | oil fired arch | oil fired evaporator arch

évaporateur à mazout


oil firing | oil fuel firing | fuel oil burning

chauffe au mazout


accidental poisoning by gases or fumes on ship atomic reactor malfunction in watercraft crushed by falling object on ship excessive heat in:boiler room | engine room | evaporator room | fire room | explosion of boiler on steamship fall from one level to another in watercraft fall on stairs or ladders in watercraft injuries in watercraft caused by:deck | engine room | galley | laundry | loading | machinery | localized fire on ship machinery accident in watercraft

accident de machine sur le bateau chaleur excessive dans la:chaufferie | salle des:chaudières | évaporateurs | machines | chute dans des escaliers ou des échelles sur le bateau chute d'un niveau à un autre sur le bateau écrasement par un objet tombé sur le bateau explosion d'une chaudière sur un bateau à vapeur incendie localisé à bord d'un bateau intoxication accidentelle par des gaz et des fumées sur un bateau lésions traumatiques provoquées sur le bateau par les machines de:blanchisserie | chargement | cuisine | pont | salle des machines | mauvais fonctionnement d'un réacteur atomique à bord d'un bateau
IN-CONTEXT TRANSLATIONS
(2) In every Class A ship fitted with main or auxiliary oil-fired boilers, or internal combustion propelling machinery, the arrangements of sea connections, pumps, and the sources of power for operating them, shall be such as will ensure that a fire in any one compartment will not put all the fire pumps out of action; fire pumps shall not all be located in the same compartment but shall be arranged so that at least one pump and its source of power will remain available if a fire in any one compartment would make it impossible to use the other pump or pumps or their source of power; in some cases this requirement ca ...[+++]

(2) Sur tout navire de la classe A muni de chaudières principales ou auxiliaires chauffées au mazout ou mû par des moteurs à combustion interne, les prises d’eau à la mer, les pompes et les sources d’énergie qui les actionnent seront disposées de manière à éviter qu’un incendie dans l’un quelconque des compartiments puisse mettre toutes les pompes d’incendie hors de service. Les pompes d’incendie ne seront pas toutes placées dans le même compartiment mais seront disposées de façon qu’au moins l’une d’elles et sa source d’énergie soient utilisables au cas où un incendie dans un compartiment viendrait à rendre impossible l’utilisation de l ...[+++]


(5) The arrangements for distributing foam in connection with oil-fired boilers and oil fuel units, shall be such that it can be directed at will either onto the tank top beneath the boiler by means of the fixed distribution pipes, or by hose and nozzle to such places above the floor plates as boiler fronts and oil fuel units; the distribution pipes shall be of steel, galvanized inside and outside.

(5) En ce qui concerne les chaudières chauffées au mazout et les appareils à mazout, il devra être possible de diriger la mousse soit, au moyen de tuyaux de distribution fixes, sur le plafond de ballast sous les chaudières, soit, au moyen d’une manche et d’un ajutage, sur certains points situés au-dessus des tôles de parquet, par exemple les façades de chaudière et les appareils à mazout; les tuyaux de distribution seront en acier, galvanisés tant à l’intérieur qu’à l’extérieur.


(3) Every Class B ship propelled by internal combustion machinery and having an auxiliary oil-fired boiler situated in the compartment containing the machinery shall, in addition to the requirements of subsections (1) and (2), be provided with at least one foam fire extinguisher of not less than 9 L capacity or one equivalent fire extinguisher as set out in Schedule IV suitably stowed in the vicinity of the boiler.

(3) Tout navire de la classe B mû par des moteurs à combustion interne et ayant une chaudière auxiliaire chauffée au mazout dans le compartiment renfermant ces moteurs, doit satisfaire aux exigences des paragraphes (1) et (2), mais aussi avoir au moins un extincteur à mousse d’une capacité d’au moins 9 L ou un extincteur équivalent indiqué à l’annexe IV, dûment rangé à proximité de la chaudière.


(3) Every Class G ship propelled by internal combustion machinery and having an auxiliary oil-fired boiler situated in the compartment containing that machinery shall, in addition to the requirements of subsections (1) and (2), be provided with at least one foam fire extinguisher of not less than 9 L capacity or one equivalent fire extinguisher as set out in Schedule IV, suitably stowed in the vicinity of the boiler.

(3) Tout navire de la classe G mû par des moteurs à combustion interne et ayant une chaudière auxiliaire chauffée au mazout située dans le compartiment renfermant ces moteurs, doit satisfaire aux exigences des paragraphes (1) et (2), mais aussi avoir au moins un extincteur à mousse d’une capacité d’au moins 9 L, ou un extincteur équivalent indiqué à l’annexe IV, dûment rangé à proximité de la chaudière.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(3) Every Class H ship not over 45.7 m in length propelled by internal combustion machinery and having an auxiliary oil-fired boiler situated in the compartment containing that machinery shall, in addition to the requirements of subsections (1) and (2), be provided with at least one foam fire extinguisher of not less than 9 L capacity or one equivalent fire extinguisher as set forth in Schedule IV, suitably stowed in the vicinity of the boiler.

(3) Tout navire de la classe H d’une longueur d’au plus 45,7 m, mû par des moteurs à combustion interne et ayant une chaudière chauffée au mazout située dans le compartiment renfermant ces moteurs, doit satisfaire aux exigences des paragraphes (1) et (2), mais aussi avoir au moins un extincteur à mousse d’au moins 9 L, ou un extincteur équivalent indiqué à l’annexe IV, dûment rangé à proximité de la chaudière.


(13) As medium combustion plants firing refinery fuels alone or with other fuels for the production of energy within mineral oil and gas refineries, and recovery boilers within installations for the production of pulp, are subject to emission levels associated with best available techniques (BAT) set out in BAT conclusions already established under Directive 2010/75/EU, this Directive should not apply to such plants.

(13) Étant donné que les installations de combustion moyennes utilisant des combustibles de raffinerie seuls ou avec d'autres combustibles pour la production d'énergie au sein de raffineries de pétrole et de gaz, ainsi que les chaudières de récupération au sein d'installations de production de pâte à papier, sont soumises à des niveaux d'émission associés aux meilleures techniques disponibles (MTD) énoncés dans les conclusions sur les MTD déjà établies au titre de la directive 2010/75/UE, la présente directive ne devrait pas s'appliquer à ces installations.


(13) As medium combustion plants firing refinery fuels alone or with other fuels for the production of energy within mineral oil and gas refineries, and recovery boilers within installations for the production of pulp, are subject to emission levels associated with best available techniques (BAT) set out in BAT conclusions already established under Directive 2010/75/EU, this Directive should not apply to such plants.

(13) Étant donné que les installations de combustion moyennes utilisant des combustibles de raffinerie seuls ou avec d'autres combustibles pour la production d'énergie au sein de raffineries de pétrole et de gaz, ainsi que les chaudières de récupération au sein d'installations de production de pâte à papier, sont soumises à des niveaux d'émission associés aux meilleures techniques disponibles (MTD) énoncés dans les conclusions sur les MTD déjà établies au titre de la directive 2010/75/UE, la présente directive ne devrait pas s'appliquer à ces installations.


(9c) It should be possible for Member States not to apply this Directive to installations covered by Chapter II of Directive 2010/75/EU for pollutants for which emission limit values apply pursuant to this Directive when those emission limit values do not exceed the limits laid out in Annex II of this Directive, unless those are plants firing fuels in mineral oil and gas refineries or recovery boilers used in pulp production.

(9 quater) Les États membres devraient pouvoir ne pas appliquer la présente directive aux installations relevant du chapitre II de la directive 2010/75/UE pour les polluants auxquels des valeurs limites d'émission s'appliquent conformément à la présente directive lorsque ces valeurs limites d'émission ne dépassent pas les limites fixées à l'annexe II de la présente directive, à moins que ces installations utilisent des combustibles dans des raffineries de pétrole et de gaz ou des chaudières de récupération utilisées dans la production de pâte.


In the case of combustion plants firing fuels in mineral oil and gas refineries and in the case of recovery boilers used in pulp production, on a request by an operator of a medium combustion plant Member States shall exempt medium combustion plants which are part of an installation covered by Chapter II of Directive 2010/75/EU from compliance with the emission limit values set out in Annex II and the provisions of Article 6 of this Directive for those pollutants for which emission limit values apply pursuant to the provisions of arti ...[+++]

Dans le cas des installations de combustion utilisant des combustibles dans des raffineries de pétrole et de gaz ou des chaudières de récupération utilisées dans la production de pâte, les États membres peuvent, sur demande d'un exploitant d'une installation de combustion moyenne, exempter les installations de combustion moyennes qui font partie d'une installation relevant du chapitre II de la directive 2010/75/UE du respect des valeurs limites d'émission prévues à l'annexe II et des dispositions de l'article 6 de la présente directive concernant les polluants pour lesquels des valeurs limites d'émission s'appliquent, conformément aux di ...[+++]


- for SO2 from gas turbines or boilers firing oil with known sulphur content in cases where there is no desulphurisation equipment.

- pour le SO2 provenant de turbines à gaz ou de brûleurs brûlant du mazout à teneur en soufre connue en cas d'absence d'équipement de désulfuration,




Anderen hebben gezocht naar : engine room     evaporator room     fire room     fuel oil burning     galley     gas-oil fired boiler     laundry     liquid fuel boiler     loading     machinery     mazout boiler     oil boiler     oil fired arch     oil fired evaporator arch     oil firing     oil firing boiler     oil fuel firing     oil furnace     oil-fired boiler     oil-fired evaporator     oil-firing boiler     oil-fuel boiler     Oil-firing boiler     


datacenter (1): www.wordscope.be (v4.0.br)

'Oil-firing boiler' ->

Date index: 2022-12-27
w