Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Aerosol can air tank pressurized-gas tank
Callier coefficient
Callier factor
Callier quotient
Callier's Q factor
Check tank thermometer
Dock
Fall from or into cavity
Fuel storage tank monitoring
Haystack
Hole
Monitor fuel storage tanks
Monitor tank thermometer
Monitoring diesel and gasoline storage tanks
Monitoring fuel storage tanks
Monitoring tank thermometer
Pit
Q factor
Q-factor
Q-tank
Quarry
Quenching tank reservoir
Quick-acting ballast tank
Shaft
TS
Take care of acidulation tanks
Tank
Tank lighter
Tank thermometer monitoring
Tank vessel
Tank-ship
Tanker
Tanker ship
Tend acidulation tanks
Tending acidulation tanks
Watch acidulation tanks
Well

Vertaling van "Q-tank " (Engels → Frans) :

TERMINOLOGIE
quick-acting ballast tank [ Q-tank ]

ballast de plongée rapide [ Q-tank ]


aerosol can air tank pressurized-gas tank

bombe aérosol réservoir de:air | gaz sous pression |


check tank thermometer | tank thermometer monitoring | monitor tank thermometer | monitoring tank thermometer

surveiller le thermomètre d’une cuve


take care of acidulation tanks | tending acidulation tanks | tend acidulation tanks | watch acidulation tanks

utiliser des bacs d’acidulation


fuel storage tank monitoring | monitoring fuel storage tanks | monitor fuel storage tanks | monitoring diesel and gasoline storage tanks

surveiller des cuves de stockage de carburant


tank lighter | tank vessel | tanker | tanker ship | tank-ship | T/S [Abbr.] | TS [Abbr.]

barge-citerne | navire-citerne | pétrolier


quenching tank reservoir

noyade et submersion dans:cuve de trempage | réservoir |


fall from or into:cavity | dock | haystack | hole | pit | quarry | shaft | tank | well |

chute dans ou du haut de:bassin | carrière | cavité | fosse | meule de foin | puits | réservoir | trou |


Q number, Q level, Q precedence

nombre Q, niveau Q, préséance Q


Callier coefficient [ Callier quotient | Q factor | Q-factor | Callier factor | Callier's Q factor ]

coefficient de Callier
IN-CONTEXT TRANSLATIONS
(2) In respect of any single-walled underground tank other than a steel tank or a reinforced plastic tank, the owner or operator must, within one year after the day on which these Regulations come into force, provide the Minister with a declaration, dated after the coming into force of these Regulations and signed by a professional engineer, stating that the tank has normal and emergency venting, the walls of the tank and its floor are impervious to the passage of petroleum product or allied petroleum product, the tank’s structural integrity is maintained and the tank is suitable for the storage of petroleum products or allied petroleum ...[+++]

(2) Pour tous les réservoirs souterrains à paroi simple autres qu’en acier ou en plastique renforcé, le propriétaire ou l’exploitant doit transmettre au ministre, dans l’année suivant la date de l’entrée en vigueur du présent règlement, une déclaration datée après la date de l’entrée en vigueur du présent règlement et signée par un ingénieur, selon laquelle le réservoir est doté d’une ventilation normale et de secours, les parois et le fond du réservoir empêchent le passage de produits pétroliers ou de produits apparentés, l’intégrité structurale du réservoir est maintenue et le réservoir convient au stockage de produits pétroliers ou de ...[+++]


(b) deep tanks and peak tanks used for the carriage of water, and deep tanks and double bottom tanks arranged for the carriage of oil fuel: a head of water equal to the maximum head to which the tanks can be subjected in service but not less than 2.44 m above the crown of the tanks where the moulded depth to the strength deck exceeds 4.88 m, and 0.91 m where the moulded depth does not exceed 3.05 m; intermediate heads may be obtained by interpolation between 4.88 m and 3.05 m;

b) les cales à eau et les coquerons devant servir au transport de l’eau ainsi que les cales à eau et les double-fonds aménagés pour le transport du mazout : une charge d’eau égale à la charge maximum à laquelle ils peuvent être soumis en service mais atteignant au moins 2,44 m au-dessus de leur sommet lorsque le creux sur quille au pont de résistance dépasse 4,88 m, et au moins 0,91 m lorsqu’il ne dépasse pas 3,05 m; les charges intermédiaires s’obtiennent par interpolation entre 4,88 m et 3,05 m;


(b) deep tanks and peak tanks used for the carriage of water, and deep tanks and double bottom tanks arranged for the carriage of oil fuel: a head of water equal to the maximum head to which the tanks can be subjected in service but not less than 2.44 m above the crown of the tanks where the moulded depth to the strength deck exceeds 4.88 m, and 0.91 m where the moulded depth does not exceed 3.05 m; intermediate heads may be obtained by interpolation between 4.88 m and 3.05 m;

b) les cales à eau et les coquerons devant servir au transport de l’eau ainsi que les cales à eau et les double-fonds aménagés pour le transport du mazout : une charge d’eau égale à la charge maximum à laquelle ils peuvent être soumis en service mais atteignant au moins 2,44 m au-dessus de leur sommet lorsque le creux sur quille au pont de résistance dépasse 4,88 m, et au moins 0,91 m lorsqu’il ne dépasse pas 3,05 m; les charges intermédiaires s’obtiennent par interpolation entre 4,88 m et 3,05 m;


(b) deep tanks and peak tanks used for carrying water, and deep tanks and double bottom tanks arranged for carrying oil fuel shall be tested to a head of water equal to the maximum head to which the tanks can be subjected in service, but not less than 2.44 m above the crown of the tanks where the moulded depth to the strength deck exceeds 4.88 m, and 915 mm where the moulded depth does not exceed 3.05 m; intermediate heads may be obtained by interpolation between 4.88 and 3.05 m;

b) les cales à eau et les coquerons devant servir au transport de l’eau ainsi que les cales à eau et les doubles-fonds aménagés pour le transport du mazout seront éprouvés sous une charge d’eau égale à la charge maximum à laquelle ils pourront être soumis en service mais atteignant au moins 2,44 m au-dessus de leur sommet lorsque le creux sur quille jusqu’au pont de résistance dépasse 4,88 m et au moins 915 mm lorsque le creux sur quille ne dépasse pas 3,05 m; les charges intermédiaires s’obtiennent par interpolation entre 4,88 m et 3,05 m;


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(c.4) subject to paragraphs (c.5) and (c.6), where the capacity of a fuel tank is more than 114 L, the tank is made of material other than steel and the thickness of the tank’s plating is such as to provide a strength equal to or greater than the strength of steel plating having a thickness set out in Column I of an item of the table to paragraph (c.2), the tank shall be fitted with stiffeners so that the unsupported flat surfaces of the tank do not exceed, in square metres, the area set out in Column II of that item;

c.4) sous réserve des alinéas c.5) et c.6), lorsque la capacité d’une soute à combustible dépasse 114 L, que la soute est faite d’un matériau autre que l’acier et que l’épaisseur de la tôle offre une résistance égale ou supérieure à celle d’une tôle d’acier d’une épaisseur indiquée à la colonne I du tableau de l’alinéa c.2), la soute doit être munie de pièces de renfort de façon que les surfaces planes sans appui n’excèdent pas, en mètres carrés, la valeur indiquée à la colonne II de ce tableau;


measures to minimise evaporation from strip tanks comprising: lids for covering strip tanks except during loading and unloading; suitable loading and unloading arrangements for strip tanks; and wash tanks with water or brine to remove excess solvent after unloading.

mise en place de mesures visant à réduire au minimum l’évaporation du contenu des cuves de décapage, notamment: pose de couvercles sur les cuves de décapage, sauf pendant les opérations de chargement et de déchargement; chargement et déchargement des cuves de décapage selon les modalités appropriées et nettoyage des cuves au moyen d’eau douce ou salée pour ôter toute trace de solvant après le déchargement.


In addition to the tanks referred to in point (c)(i) of the first subparagraph, gas tanks fitted to motor vehicles designed for the direct use of gas as a fuel and tanks fitted to ancillary systems with which the vehicle may be equipped shall also be considered to be standard tanks.

Outre les réservoirs visés au premier alinéa, point c) i), sont également considérés comme réservoirs normaux les réservoirs à gaz adaptés sur des véhicules à moteur qui permettent l’utilisation directe du gaz comme carburant ainsi que les réservoirs adaptés aux systèmes auxiliaires dont peuvent être équipés les véhicules.


Content of the Annex to the Directive: Requirements for construction, equipment, type approval, inspections and tests, and marking of fixed tanks (tank-vehicles), removable tanks and tank containers and tank swap bodies, with shells made of metallic materials, and battery-vehicles and MEGCs.

Contenu de l’annexe de la directive: prescriptions relatives à la construction, aux équipements, à l’agrément de type, aux contrôles et aux épreuves et au marquage des citernes fixes (véhicules-citernes), des citernes et des conteneurs-citernes démontables et des caisses mobiles citernes, dont les réservoirs sont construits en matériaux métalliques, ainsi que des véhicules-batteries et CGEM.


Content of the national legislation: Transitional provision: Fixed tanks (tank-vehicles), removable tanks and tank containers first registered in Greece between 1 January 1985 and 31 December 2001 may be used until 31 December 2010.

Contenu de la législation nationale: disposition transitoire: les citernes fixes (véhicules-citernes), citernes et conteneurs-citernes démontables immatriculés pour la première fois en Grèce entre le 1.1.1985 et le 31.12.2001 peuvent être utilisés jusqu’au 31.12.2010.


Content of the national legislation: Exemption from the requirements of 6.7 and 6.8 of the ADR for the carriage by road of nominally empty uncleaned storage tanks (for storage at fixed premises) for the purpose of cleaning, repair, testing or scrapping, provided that (a) as much of the pipework which was connected to the tank as was reasonably practicable to remove from it has been removed; (b) a suitable pressure relief valve, which shall remain operational during the carriage, is fitted to the tank; and (c) subject to (b) above all openings in the tank and in any pipework attached thereto have been sealed to prevent the escape of any ...[+++]

Contenu de la législation nationale: exemption des prescriptions figurant sous 6.7 et 6.8 de l’ADR pour le transport par route de citernes fixes nominalement vides et non nettoyées (pour leur entreposage dans des lieux fixes) en vue de leur nettoyage, réparation, mise à l’essai ou mise à la ferraille, à condition que: a) tous les tuyaux fixés à la citerne qu’il est raisonnablement possible d’enlever aient été enlevés; b) la citerne ait été équipée d’un dispositif de décompression adéquat, qui doit rester opérationnel pendant le transport; et c), sous réserve du point b), toutes les ouvertures dans la citerne et dans la tuyauterie fixée ...[+++]


w