Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Pump suction pipe
Stand pipe for air pump suction
Standpipe for air pump suction

Vertaling van "Stand pipe for air pump suction " (Engels → Frans) :

TERMINOLOGIE
stand pipe for air pump suction

tubulure d'aspiration d'air


standpipe for air pump suction

tubulure d'aspiration d'air


IN-CONTEXT TRANSLATIONS
273. The pump suction piping installed with a meter shall be as short and unencumbered as possible and all liquid supply systems associated with a meter shall be arranged to minimize the ingress of air, water or other foreign matter, including any liquid other than the one the meter is intended to measure.

273. La tuyauterie d’aspiration d’une installation comportant un compteur doit être aussi courte et aussi simple que possible, et tous les systèmes d’amenée au compteur doivent être agencés de manière à empêcher l’entrée de l’air, de l’eau ou d’autres corps étrangers, y compris tout liquide autre que celui qui est mesuré.


(2) The design flow velocity of sea water through the suction pipe to any pump described in subsection (1) shall not be more than 2.03 m/s.

(2) La vitesse d’écoulement prévue de l’eau de mer dans le tuyau d’aspiration de toute pompe mentionnée au paragraphe (1) ne doit pas dépasser 2,03 m/s.


Pumps required for essential services shall not be connected to a common suction manifold, a common suction pipe, a common discharge manifold or a common discharge pipe unless the arrangements are such that the working of any pump so connected will not be affected by any other pumps operating at the same time.

Les pompes nécessaires aux services essentiels ne peuvent pas être reliées à un collecteur commun d’aspiration ou de décharge ou à un tuyau commun d’aspiration ou de décharge à moins que les dispositions soient telles que le fonctionnement d’une des pompes ainsi reliées ne soit pas gêné par les autres pompes fonctionnant en même temps.


(2) The minimum total power bilge pumping capacity and the minimum internal diameter of the suction and discharge bilge piping for ships of various lengths shall be as set out in Table I of Schedule IX, but for ships of intermediate lengths the total minimum power pump capacity and minimum internal diameter of the bilge piping shall be found by interpolation.

(2) Le débit global minimum des pompes de cale mécaniques et le diamètre intérieur minimum du tuyautage d’aspiration et de décharge de cale pour les bateaux de pêche de différentes longueurs seront conformes au tableau I de l’annexe IX; dans le cas des bateaux de longueur intermédiaire, ce débit et ce diamètre s’obtiendront par interpolation.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(4) Subject to subsection (6), bilge suctions, piping and means for drainage shall be so arranged that any water that may enter a watertight compartment can be pumped out by each of the power bilge pumps required by this section when the vessel is on an even keel and is either upright or has a list of not more than five degrees.

(4) Sous réserve du paragraphe (6), les bouches d’aspiration de cale, le tuyautage et les dispositifs d’assèchement seront disposés de telle sorte que chacune des pompes de cale mécaniques exigées au présent article puisse épuiser l’eau qui s’amassera dans un compartiment étanche lorsque le bateau de pêche sera sans différence de tirant et qu’il sera droit ou aura ...[+++]


2. For air conditioning products and equipment as well as heat pumps with separate indoor and outdoor sections connected by refrigerant piping, the label information shall be placed on that part of the equipment which is initially charged with the refrigerant.

2. Pour les produits et équipements de climatisation et de pompes à chaleur comportant des sections distinctes à l’intérieur et à l’extérieur qui sont reliées par la canalisation du réfrigérant, les informations de l’étiquette sont placées sur la partie de l’équipement qui est initialement chargée avec le réfrigérant.


2. For air conditioning products and equipment as well as heat pumps with separate indoor and outdoor sections connected by refrigerant piping, the label information shall be placed on that part of the equipment which is initially charged with the refrigerant.

2. Pour les produits et équipements de climatisation et de pompes à chaleur comportant des sections distinctes à l’intérieur et à l’extérieur qui sont reliées par la canalisation du réfrigérant, les informations de l’étiquette sont placées sur la partie de l’équipement qui est initialement chargée avec le réfrigérant.


Instead of using air under pressure, a vacuum may be used (water suction pump) provided that the connections between the apparatus are air tight.

Au lieu d'utiliser de l'air sous pression, on peut également opérer au moyen du vide, à condition que les connexions de l'appareil soient étanches.


A dynamic oil separator must be installed in the piping downstream of the bilge pump or, failing this, a static separator must be fitted around each suction strainer.

Un séparateur dynamique doit être monté sur la tuyauterie en aval de la pompe de cale ou, à défaut, un séparateur statique doit être monté autour de chaque crépine d'aspiration.




Anderen hebben gezocht naar : pump suction pipe     standpipe for air pump suction     Stand pipe for air pump suction     


datacenter (1): www.wordscope.be (v4.0.br)

'Stand pipe for air pump suction' ->

Date index: 2022-10-07
w