Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Absolute air moisture
Absolute humidity
Absolute humidity of the air
Absorption band of water vapor
Aqueous vapour permeability
Band of water vapor
Density of water vapour
Dv
Impervious to water vapour
Vapor concentration
Vapor density
Vapor resistance
Vapour concentration
Vapour density
Vapour resistance
Water vapor concentration
Water vapor density
Water vapor resistance
Water vapour band
Water vapour concentration
Water vapour density
Water vapour diffusion resistance
Water vapour proof
Water vapour resistance
Water vapour resistance factor
Water vapour resistance test
Water vapour test
Water vapour transmission
Water-vapour absorption band
Water-vapour band
Water-vapour permeability
Water-vapour proof
µ

Vertaling van "Water vapour concentration " (Engels → Frans) :

TERMINOLOGIE
water vapor concentration | water vapour concentration

teneur en vapeur d'eau


absolute humidity [ dv | vapour concentration | vapor concentration | water vapor density | water vapour density | density of water vapour | vapour density | vapor density ]

humidité absolue [ dv | concentration en vapeur d'eau | concentration de la vapeur d'eau | concentration de la vapeur | concentration de vapeur ]


absolute humidity | vapor concentration | vapour concentration | water vapor density | water vapour density

concentration de la vapeur d'eau | humidité absolue


water-vapour band [ water vapour band | water-vapour absorption band | absorption band of water vapor | band of water vapor ]

bande de la vapeur d'eau [ bande d'absorption de la vapeur d'eau ]


water vapour proof | water-vapour proof | impervious to water vapour

imperméable à la vapeur d'eau | étanche à la vapeur de l'eau


water vapor resistance [ water vapour diffusion resistance | water vapour resistance | vapour resistance | vapor resistance ]

résistance à la vapeur [ résistance à la vapeur d'eau ]


water vapour resistance test | water vapour test

essai de résistance à la vapeur


water-vapour permeability | water vapour transmission | aqueous vapour permeability

perméabilité à la vapeur d'eau


water vapour resistance factor (1) | water vapour resistance factor (2) [ µ ]

facteur de résistance à la diffusion de vapeur d'eau (1) | coefficient de résistance à la diffusion de vapeur (2) [ µ ]


absolute humidity | absolute air moisture | absolute humidity of the air | vapor concentration | vapour concentration | vapor density

humidité absolue | humidité absolue de l'air
IN-CONTEXT TRANSLATIONS
The water vapour feedback effect, in the models, gets concentrated in the troposphere over the Tropics.

Cet effet, dans les modèles, est concentré dans la troposphère au-dessus des tropiques.


A NO span gas having a concentration of 80 to 100% of full scale to the normal operating range shall be passed through the (H)CLD and the NO value recorded as D. The NO gas shall be bubbled through water at room temperature and passed through the (H)CLD and NO value recorded as C. The water temperature shall be determined and recorded as F. The mixture's saturation vapour pressure that corresponds to the bubbler water temperature (F) shall be determined and recorded as G. The water vapour concentration (in %) of the mixture shall be calculated as follows:"

Un gaz d'étalonnage du NO ayant une concentration de 80 à 100 % de l'échelle complète par rapport à la plage de fonctionnement normal doit traverser le (H)CLD et la valeur de NO enregistrée en tant que valeur D. On laisse le NO gazeux barboter dans l'eau à température ambiante et à travers le (H)CLD et on enregistre la valeur de NO en tant que valeur C. La température de l'eau est déterminée et enregistrée en tant que valeur F. La pression de vapeur de satura ...[+++]


The water vapour concentration (in %) of the mixture shall be calculated as follows:

La concentration de vapeur d'eau (en %) du mélange doit être calculée comme suit:


For diesel exhaust, the maximum exhaust water vapour concentration (in %) expected during testing shall be estimated, under the assumption of a fuel atom H/C ratio of 1,8 to 1, from the maximum CO2 concentration in the exhaust gas or from the undiluted CO2 span gas concentration (A, as measured in section 1.9.2.1) as follows:"

Pour l'échappement des moteurs Diesel, la concentration maximale de la vapeur d'eau d'échappement (en %) prévue en cours d'essai doit être estimée dans l'hypothèse d'un rapport atomique H/C du carburant de 1,8 à 1, à partir de la concentration maximale de CO2 dans les gaz d'échappement ou à partir de la concentration du gaz de réglage de sensibilité au CO2 non dilué (valeur A, mesurée comme indiqué au point 1.9.2.1) comme suit:"


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
Calculation of water quench must consider dilution of the NO span gas with water vapour and scaling of water vapour concentration of the mixture to that expected during testing.

Le calcul de l'effet d'atténuation de l'eau doit tenir compte de la dilution du gaz de réglage de sensibilité au NO dans la vapeur d'eau ainsi que de la mise à l'échelle de la concentration de vapeur d'eau du mélange par rapport à celle prévue pendant l'essai.


The expected diluted NO span gas (in water vapour) concentration shall be calculated as follows:

La concentration escomptée du gaz de réglage de sensibilité au NO dilué (dans de la vapeur d'eau) se calcule comme suit:


A NO span gas having a concentration of 80 % to 100 % of full scale to the normal operating range shall be passed through the (H)CLD and the NO value recorded as D. The NO span gas shall then be bubbled through water at room temperature and passed through the (H)CLD and the NO value recorded as C. The water temperature shall be determined and recorded as F. The mixture's saturation vapour pressure that corresponds to the bubbler water temperature (F) shall be determined and recorded as G. The water vapour concentration (in %) of the mixture shall be calculated as follows:

Un gaz de réglage de sensibilité au NO qui possède une concentration de 80 % à 100 % de la pleine échelle de la gamme de détection normale doit traverser le (H)CLD et la valeur mesurée pour le NO être enregistrée en tant que valeur D. On laisse le gaz de réglage de sensibilité au NO barboter dans de l'eau à température ambiante pour passer ensuite à travers le (H)CLD et on enregistre la valeur mesurée pour le NO en tant que valeur C. La température de l'eau est déterminée et enregistrée en tant que valeur F. La pression de ...[+++]


A NO span gas having a concentration of 80 to 100 % of full scale to the normal operating range shall be passed through the (H)CLD and the NO value recorded as D. The NO gas shall then be bubbled through water at room temperature and passed through the (H)CLD and the NO value recorded as C. The water temperature shall be determined and recorded as F. The mixture's saturation vapour pressure that corresponds to the bubbler water temperature (F) shall be determined and recorded as G. The water vapour concentration (in %) of the mixture shall be calculated as follows:

Un gaz de réglage de sensibilité au NO qui possède une concentration de 80 % à 100 % de la pleine échelle de la gamme de détection normale doit traverser le (H)CLD et la valeur mesurée pour le NO être enregistrée en tant que valeur D. On laisse le gaz de réglage de sensibilité au NO barboter dans de l'eau à temperature ambiante pour passer ensuite à travers le (H)CLD et on enregistre la valeur mesurée pour le NO en tant que valeur C. La température de l'eau est déterminée et enregistrée en tant que valeur F. La pression de ...[+++]


A NO span gas having a concentration of 80 to 100 % of full scale of the normal operating range shall be passed through the (H)CLD and the NO value recorded as D. The NO span gas shall then be bubbled through water at room temperature and passed through the (H)CLD and the NO value recorded as C. The analyser's absolute operating pressure and the water temperature shall be determined and recorded as E and F, respectively. The mixture's saturation vapour pressure that corresponds to the bubbler water temperature F shall be determined and recorded as G. The water vapour concentration (H, in %) of the mixture shall be calculated as follows:

Un gaz de réglage de sensibilité au NO qui possède une concentration de 80 à 100 % de la pleine échelle de la gamme opératoire normale est envoyé à travers le (H)CLD et la valeur mesurée pour le NO est enregistrée comme D. Le gaz de réglage de sensibilité au NO est ensuite purifié par barbotage dans de l'eau à la température ambiante et envoyé à travers le (H)CLD; la valeur mesurée pour le NO est enregistrée comme C. La pression de service absolue de l'analyseur et la température de l'eau sont déterminées et enregistrées respectiveme ...[+++]


A NO span gas having a concentration of 80 to 100 % of full scale to the normal operating range shall be passed through the (H)CLD and the NO value recorded as D. The NO gas shall be bubbled through water at room temperature and passed through the (H)CLD and the NO value recorded as C. The analyser's absolute operating pressure and the water temperature shall be determined and recorded as E and F, respectively. The mixture's saturation vapour pressure that corresponds to the bubbler water temperature (F) shall be determined and recorded as G. The water vapour concentration (in %) of the mixture shall be calculated as follows:

Un gaz d'étalonnage du NO ayant une concentration de 80 à 100 % de l'échelle complète par rapport à la plage de fonctionnement normal doit traverser le (H)CLD et la valeur de NO enregistrée en tant que valeur D. On laisse le NO gazeux barboter dans l'eau à température ambiante et à travers le (H)CLD et on enregistre la valeur de NO en tant que valeur C. La pression de fonctionnement absolu de l'analyseur et la température de l'eau doivent être déterminées et enregistrées respectivement en tant que valeurs E et F. La pr ...[+++]


w