Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
CLHPO
Electric transformer
General price-level loss
High-voltage power transformer repairer
High-voltage power transformer repairman
High-voltage power transformer repairwoman
Loss of purchasing power
Loss on net monetary position
Mobile power transformer station for work-yards
Monetary loss
Output mismatch loss
Power mismatch loss
Power transformation loss
Power transformer
Power transformer repairer
Power transformer repairman
Power transformer repairwoman
Price-level loss
Purchasing power loss
Reverse power mismatch loss
Transformer

Vertaling van "power transformation loss " (Engels → Frans) :

TERMINOLOGIE
power transformation loss

perte relative à la transformation du courant


purchasing power loss [ general price-level loss | loss on net monetary position | price-level loss | loss of purchasing power | monetary loss ]

perte de pouvoir d'achat [ perte de pouvoir d'achat sur la situation monétaire nette | perte due à l'évolution du niveau général des prix | perte due à l'évolution des prix | perte d'inflation ]


output mismatch loss | power mismatch loss | reverse power mismatch loss

perte par désadaptation de sortie


power transformer repairman [ power transformer repairwoman | power transformer repairer ]

réparateur de transformateurs de puissance [ réparatrice de transformateurs de puissance | dépanneur de transformateurs de puissance | dépanneuse de transformateurs de puissance ]


high-voltage power transformer repairer [ high-voltage power transformer repairman | high-voltage power transformer repairwoman ]

réparateur de transformateurs de haute tension [ réparatrice de transformateurs de haute tension ]


electric transformer | power transformer | transformer

transformateur | transformateur de puissance | transformateur électrique


mobile power transformer station for work-yards

poste de transformation mobile pour chantiers






Ordinance of 25 October 1995 on Compensation for Losses due to the Use of Hydraulic Power [ CLHPO ]

Ordonnance du 25 octobre 1995 sur la compensation des pertes subies dans l'utilisation de la force hydraulique [ OCFH ]
IN-CONTEXT TRANSLATIONS
Medium power transformers shall comply with the maximum allowed load and no-load losses or the Peak Efficiency Index (PEI) values set out in Tables I. 1 to I. 5, excluding medium power pole-mounted transformers, which shall comply with the maximum allowed load and no load losses values set out in Table I. 6.

Les transformateurs de moyenne puissance respectent les maxima autorisés pour les pertes dues à la charge et les pertes à vide, ou les valeurs de l'indice d'efficacité maximale (PEI), définis dans les tableaux I. 1 à I. 5, à l'exception des transformateurs de moyenne puissance sur poteau qui respectent les maxima autorisés pour les pertes dues à la charge et les pertes à vide définis dans le tableau I. 6.


The methodology for calculating the Peak Efficiency Index (PEI) for medium and large power transformers is based on the ratio of the transmitted apparent power of a transformer minus the electrical losses to the transmitted apparent power of the transformer.

La méthode employée pour calculer l'indice d'efficacité maximale (PEI) des transformateurs de moyenne puissance et de grande puissance est fondée sur le rapport entre la puissance apparente transmise d'un transformateur moins les pertes électriques et la puissance apparente transmise du transformateur.


‘Peak Efficiency Index’ (PEI) means the maximum value of the ratio of the transmitted apparent power of a transformer minus the electrical losses to the transmitted apparent power of the transformer.

«indice d'efficacité maximale» (PEI), la valeur maximale du rapport entre la puissance apparente transmise d'un transformateur moins les pertes électriques et la puissance apparente transmise du transformateur.


No load loss’ (Po) means the active power absorbed at rated frequency when the transformer is energised and the secondary circuit is open.

«pertes à vide» (Po), la puissance active absorbée à la fréquence assignée lorsque le transformateur est sous tension et que le circuit secondaire est ouvert.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
17. Emphasises the important role of supply side energy efficiency ; points out that transmission and distribution, contribute considerably to energy loss (notably in generators and transformers, as well as those resulting from excessively high resistances during transmission) and that shortening excessively long conversion chains for converting one type of energy into another electricity represents a major source of savings; stresses the role that microgeneration and decentralised and diversified generation might play in guaranteeing supply security an ...[+++]

17. souligne le rôle important dévolu à une efficacité énergétique axée sur l'offre; souligne que le transport et la distribution contribuent dans une large mesure aux pertes d'énergie (notamment dans les générateurs ou les onduleurs de courant ainsi que par suite d'une résistance électrique excessive au cours de sa distribution) et que raccourcir des processus excessivement longs de conversion d'un type d'énergie à un autre type d'énergie électrique représente une source d'économies majeures; souligne le rôle que la microgénération ...[+++]


17. Emphasises the important role of supply side energy efficiency ; points out that transmission and distribution, contribute considerably to energy loss (notably in generators and transformers, as well as those resulting from excessively high resistances during transmission) and that shortening excessively long conversion chains for converting one type of energy into another electricity represents a major source of savings; stresses the role that microgeneration and decentralised and diversified generation might play in guaranteeing supply security an ...[+++]

17. souligne le rôle important dévolu à une efficacité énergétique axée sur l'offre; souligne que le transport et la distribution contribuent dans une large mesure aux pertes d'énergie (notamment dans les générateurs ou les onduleurs de courant ainsi que par suite d'une résistance électrique excessive au cours de sa distribution) et que raccourcir des processus excessivement longs de conversion d'un type d'énergie à un autre type d'énergie électrique représente une source d'économies majeures; souligne le rôle que la microgénération ...[+++]


other equipment and appliances (e.g. combined heat and power appliances, new efficient devices, time control for optimised energy use, stand-by loss reduction, installation of capacitors to reduce reactive power, transformers with low losses).

autres équipements et appareils (exemples: appareils de production combinée de chaleur et d'électricité, nouveaux dispositifs efficaces, systèmes de temporisation assurant une optimisation de la consommation d'énergie, systèmes de réduction des pertes en mode de veille, installation de condensateurs destinés à limiter la puissance réactive, transformateurs à faibles pertes).


For electricity, includes losses in transformers which are not considered as integral parts of the power plants.

Pour l'électricité, les pertes dans les transformateurs qui ne sont pas considérés comme faisant partie intégrante des centrales sont incluses.


other equipment and appliances (e.g. combined heat and power appliances, new efficient devices, time control for optimised energy use, stand-by loss reduction, installation of capacitors to reduce reactive power, transformers with low losses);

autres équipements et appareils (exemples: appareils de production combinée de chaleur et d'électricité, nouveaux dispositifs efficaces, systèmes de temporisation assurant une optimisation de la consommation d'énergie, systèmes de réduction des pertes en mode de veille, installation de condensateurs destinés à limiter la puissance réactive, transformateurs à faibles pertes);


other equipment and appliances (e.g. combined heat and power appliances, new, efficient devices, time control for optimised energy use, stand-by loss reduction, installation of capacitors to reduce reactive power, transformers with low losses);

autres équipements et appareils (ex.: appareils de production combinée de chaleur et d'électricité, nouveaux dispositifs efficaces, systèmes de temporisation assurant une optimisation de la consommation d'énergie, systèmes de réduction des pertes en mode de veille, installation de condensateurs destinés à limiter la puissance réactive, transformateurs à faibles pertes);


w