Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Total-exhaust CVS system
Total-exhaust constant-volume sampling system

Traduction de «total-exhaust cvs system » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
total-exhaust constant-volume sampling system [ total-exhaust CVS system ]

système d'échantillonnage à volume constant de la totalité des gaz d'échappement
TRADUCTIONS EN CONTEXTE
During a prescribed transient cycle of warmed-up engine operating conditions, which is based closely on road-type-specific driving patterns of heavy-duty engines installed in trucks and buses, the above pollutants shall be examined either after diluting the total exhaust gas with conditioned ambient air (CVS system with double dilution for particulates) or by determining the gaseous components in the raw exhaust gas and the particulates with a partial flow dilution system.

Durant un cycle transitoire prescrit de conditions de fonctionnement d’un moteur chaud, qui reflète fidèlement les modes de conduite typiquement routiers de moteurs de poids lourds et de bus, les polluants susmentionnés sont analysés après avoir dilué la totalité du volume de gaz d’échappement dans de l’air ambiant conditionné (système de prélèvement à volume constant avec double dilution pour les particules) ou en déterminant les éléments constitutifs des gaz d’échappement bruts et les particules avec un système à dilution en dérivation.


2.2.1. Determination of the Diluted Exhaust Gas Flow PDP-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust is kept within ± 6 K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x V0 x NP x (pB - p1 ) x273 / (101,3 x T) where M TOTW = mass of the diluted exhaust gas on wet basis over the cycle V0 = volume of gas pumped per revolution under test conditions (m³/rev) NP = total revolutions of pump per test pB = atmospheric pressure in the test cell (kPa) p1 = pressure drop below atmospheric at the pump inlet (kPa) T = average temperature of the diluted exhaust gas at ...[+++]

2.2.1. Détermination du débit de gaz d'échappement dilués Système PDP-CVS Le débit massique durant le cycle est calculé comme suit si la température des gaz d'échappement dilués est maintenue dans une limite de ± 6 K durant tout le cycle à l'aide d'un échangeur de chaleur: M TOTW = 1,293 x V0 x NP x (pB - p1 ) x 273 / (101,3 x T) où: MTOTW = masse de gaz d'échappement dilués en conditions humides durant le cycle (en kg) V0 = volume de gaz pompé par tour dans les conditions d'essai (en m³/tr) NP = nombre total de tours de la pompe par essai PB = pression atmosphérique dans la chambre d'essai (en kPa) p1 = dépression sous la pression atmos ...[+++]


In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: M TOTW ,i = 1,293 x V0 x NP,i x (pB - p1 ) x 273 / (101,3 x T) where NP,i = total revolutions of pump per time interval CFV-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust gas is kept within ± 11K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x t x Kv x pA / T where M TOTW = mass ...[+++]

Dans ce cas, la masse instantanée de gaz d'échappement dilués est calculée comme suit: M TOTW ,i = 1,293 x V0 x NP,i x (pB - p1 ) x 273 / (101,3 x T) où: NP,i = nombre total de tours de la pompe par intervalle de temps Système CFV-CVS Le débit massique durant le cycle est calculé comme suit si la température des gaz d'échappement dilués est maintenue dans une limite de ± 11 K durant tout le cycle à l'aide d'un échangeur de chaleur: M TOTW = 1,293 x t x Kv x pA / T où: MTOTW = masse de gaz d'échappement dilués en conditions humides durant le cycle (en kg) t = temps de cycle (en s) KV = coefficient d'étalonnage du venturi à écoulement crit ...[+++]


A dilution system is described based upon the dilution of the total exhaust using the constant volume sampling (CVS) concept.

Le système de dilution décrit fonctionne sur le principe de la dilution du volume total des gaz d'échappement, selon la méthode de prélèvement à volume constant (CVS).


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
where G EDFW ,i = instantaneous equivalent diluted exhaust mass flow rate (kg/s) G EXHW ,i = instantaneous exhaust mass flow rate (kg/s) q i = instantaneous dilution ratio G TOTW ,I = instantaneous diluted exhaust mass flow rate through dilution tunnel (kg/s) G DILW ,i = instantaneous dilution air mass flow rate (kg/s) f = data sampling rate (Hz) n = number of measurements (b) where M f = particulate mass sampled over the cycle (mg) r s = average sample ratio over the test cycle where where M SE = sampled exhaust mass over the cycle (kg) M EXHW = total exhaust mass flow over the cycle (kg) M SAM = mass of diluted exhaust gas passing the ...[+++]

où: GEDFW,i = débit massique instantané équivalent de gaz d'échappement dilués (en kg/s) GEXHW,i = débit massique instantané de gaz d'échappement (en kg/s) qi = taux de dilution instantané GTOTW,i = Débit massique instantané de gaz d'échappement dilués dans le tunnel de dilution (en kg/s) GDILW,i = débit massique instantané d'air de dilution (en kg/s) f = fréquence de collecte des données (en Hz) n = nombre de mesures b) où: Mf = masse de particules prélevées durant le cycle (en mg) rs = rapport d'échantillonnage moyen sur la durée du cycle d'essai où: où: MSE = masse de gaz d'échappement prélevée sur la durée du cycle (en kg) MEXHW = débit massique total de gaz d'échappement sur la durée du cycle (en kg) MSAM = masse de gaz d'échappement d ...[+++]


Static exhaust back pressure measured with the CVS system operating shall remain within ± 1,5 kPa of the static pressure measured without connection to the CVS at identical engine speed and load.

La pression statique mesurée avec le système CVS ne doit pas dépasser de ± 1,5 kPa la pression statique mesurée en l'absence de CVS avec un régime et une charge du moteur identiques.


A dilution system is described in Figure 20 based upon the dilution of the total exhaust using the CVS (Constant Volume Sampling) concept.

La figure 20 décrit un système de dilution qui repose sur la dilution des gaz d'échappement à l'aide du concept CVS (échantillonnage à volume constant).


A dilution system is described based upon the dilution of the total exhaust using the constant volume sampling (CVS) concept.

Le système de dilution décrit fonctionne sur le principe de la dilution du volume total des gaz d'échappement, selon la méthode de prélèvement à volume constant (CVS).


The system to be used is the constant volume sampler (CVS) system. This requires that the vehicle exhaust be continuously diluted with ambient air under controlled conditions. In the constant volume sampler concept of measuring two conditions must be satisfied : the total volume of the mixture of exhaust gases and dilution air must be measured and a continuously proportional sample of the volume must be collected for analysis.

Pour la mesure des émissions massiques par ce procédé, deux conditions doivent être remplies : le volume total du mélange de gaz d'échappement et d'air de dilution doit être mesuré et un échantillon proportionnel de ce volume doit être collecté pour analyse.


A particulate sampling system is described based upon the dilution of the total exhaust using the CVS (Constant Volume Sampling) concept.

On trouvera ci-après la description d'un système de prélèvement des particules basé sur la dilution en circuit principal des gaz d'échappement qui utilise le concept CVS (Constant Volume Sampling = prélèvement à volume constant).




datacenter (1): www.wordscope.be (v4.0.br)

'total-exhaust cvs system' ->

Date index: 2023-03-21
w