Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Air-to-water heat pump
Air-water heat pump
Water-to-water heat pump

Traduction de «Air-to-water heat pump » (Anglais → Néerlandais) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous




TRADUCTIONS EN CONTEXTE
Commission Implementing Regulation (EU) 2015/2067 of 17 November 2015 establishing, pursuant to Regulation (EU) No 517/2014 of the European Parliament and the Council, minimum requirements and the conditions for mutual recognition for the certification of natural persons as regards stationary refrigeration, air conditioning and heat pump equipment, and refrigeration units of refrigerated trucks and trailers, containing fluorinated greenhouse gases and for the certification of companies as regards stationary refrigeration, air conditioning and heat pump equipment, containing fluorinated greenhouse ...[+++]

Uitvoeringsverordening (EU) 2015/2067 van de Commissie van 17 november 2015 tot vaststelling, ingevolge Verordening (EU) nr. 517/2014 van het Europees Parlement en de Raad, van minimumeisen en de voorwaarden voor wederzijdse erkenning voor de certificering van natuurlijke personen betreffende stationaire koel-, klimaatregelings- en warmtepompapparatuur en koeleenheden op koelwagens en koelaanhangwagens die gefluoreerde broeikasgassen bevatten, en voor de certificering van bedrijven betreffende stationaire koel-, klimaatregelings- en warmtepompapparatuur die gefluoreerde broeikasgassen bevat (zie bladzijde 28 van dit Publicatieblad).


For air-to-water heat pumps: Rated air flow rate, outdoors

Voor lucht/water-warmtepompen: nominaal luchtdebiet, buiten


For air-to-water heat pumps: Tj = – 15 °C (if TOL

Voor lucht/water-warmtepompen: Tj = – 15 °C (als TOL


‘operation limit temperature’ (TOL) means the outdoor temperature declared by the manufacturer for heating, below which the air-to-water heat pump space heater or air-to-water heat pump combination heater will not be able to deliver any heating capacity and the declared capacity for heating is equal to zero, expressed in degrees Celsius.

40. „uiterste bedrijfstemperatuur” (TOL): de door de fabrikant opgegeven buitentemperatuur voor verwarming waaronder het ruimteverwarmingstoestel met lucht-water-warmtepomp of het combinatieverwarmingstoestel met lucht-water-warmtepomp niet in staat is tot afgifte van verwarmingsvermogen en het opgegeven verwarmingsvermogen gelijk is aan nul, uitgedrukt in graden Celsius.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
On pages 32 and 33, in point 3.6, ‘Default values for SPF and Qusable for heat pumps’ tables 1 and 2, the values for HHP (annual equivalent heat pump hours) for reversible (using aerothermal energy) air to air and air to water heat pumps operating in ‘warm’ climates, line 3 and 4 respectively of column 3:

Bladzijde 32 en 33 in hoofdstuk 3.6 betreffende „Standaardwaarden voor SPF en Qusable voor warmtepompen”, tabel 1 en 2, de waarden voor HHP (jaarlijks equivalent aan warmtepompuren) voor omkeerbare (gebruikmakend van aerothermische energie) lucht/lucht- en lucht/water-warmtepompen die werken in een „warmer klimaat”, respectievelijk lijn 3 en 4 van kolom 3:


‘operation limit temperature’ (TOL) means the outdoor temperature declared by the manufacturer for heating, below which the air-to-water heat pump space heater or air-to-water heat pump combination heater will not be able to deliver any heating capacity and the declared capacity for heating is equal to zero, expressed in degrees Celsius;

40. „uiterste bedrijfstemperatuur” (TOL): de door de fabrikant opgegeven buitentemperatuur voor verwarming waaronder het ruimteverwarmingstoestel met lucht-water-warmtepomp of het combinatieverwarmingstoestel met lucht-water-warmtepomp niet in staat is tot afgifte van verwarmingsvermogen en het opgegeven verwarmingsvermogen gelijk is aan nul, uitgedrukt in graden Celsius;


This Regulation establishes minimum requirements for the certification of natural persons carrying out the activities referred to in Article 2(1) in relation to refrigeration units of refrigerated trucks and trailers, stationary refrigeration, air conditioning and heat pump equipment containing fluorinated greenhouse gases and certification of companies carrying out the activities referred to in Article 2(2) in relation to stationary refrigeration, air conditioning and heat pump equipment cont ...[+++]

Bij deze verordening worden minimumeisen vastgesteld voor de certificering van natuurlijke personen die de in artikel 2, lid 1, bedoelde activiteiten uitvoeren met betrekking tot koeleenheden op koelwagens en koelaanhangwagens, en stationaire koel-, klimaatregelings- en warmtepompapparatuur die gefluoreerde broeikasgassen bevatten, en voor de certificering van bedrijven die de in artikel 2, lid 2, bedoelde activiteiten uitvoeren met betrekking tot stationaire koel-, klimaatregelings- en warmtepompapparatuur die gefluoreerde broeikasgassen bevat, en stelt tevens de voorwaarden vast voor wederzijdse erkenning van de in overeenstemming met ...[+++]


The seasonal space heating energy efficiency ηs shall be calculated as the seasonal coefficient of performance SCOP divided by the conversion coefficient CC or the seasonal primary energy ratio SPER, corrected by contributions accounting for temperature controls and, for water-/brine-to-water heat pump space heaters and heat pump combination heaters, the electricity consumption of one or more ground water pumps.

De seizoensgebonden energie-efficiëntie van ruimteverwarming ηs wordt berekend als de seizoensgebonden prestatiecoëfficiënt SCOP gedeeld door de omrekeningscoëfficiënt CC of de seizoensgebonden primaire-energieverhouding SPER, gecorrigeerd door bijdragen die rekening houden met temperatuurregeling en, voor ruimteverwarmingstoestellen met water-/pekel-naar-water-warmtepompen en combinatieverwarmingstoestellen met warmtepomp, het energieverbruik van één of meerdere grondwaterpompen.


The seasonal space heating energy efficiency ηs shall be calculated as the seasonal coefficient of performance SCOP divided by the conversion coefficient CC or the seasonal primary energy ratio SPER, corrected by contributions accounting for temperature controls and, for water-/brine-to-water heat pump space heaters and heat pump combination heaters, the electricity consumption of one or more ground water pumps.

De seizoensgebonden energie-efficiëntie van ruimteverwarming ηs wordt berekend als de seizoensgebonden prestatiecoëfficiënt SCOP gedeeld door de omrekeningscoëfficiënt CC of de seizoensgebonden primaire-energieverhouding SPER, gecorrigeerd door bijdragen die rekening houden met temperatuurregeling en, voor ruimteverwarmingstoestellen met water-/pekel-naar-water-warmtepompen en combinatieverwarmingstoestellen met warmtepomp, het energieverbruik van één of meerdere grondwaterpompen.


on page 35, in point 4, ‘Calculation example’, the ‘annual equivalent heat pump hours’ (HHP) example for the water to water heat pump in the third row, penultimate column:

Bladzijde 35, hoofdstuk 4 met als titel „Berekeningsvoorbeeld”, het voorbeeld voor „Equivalent uren werking onder volledige belasting” (HHP) voor een water/water-warmtepomp, in de voorlaatste kolom, derde rij:




D'autres ont cherché : air-to-water heat pump     air-water heat pump     water-to-water heat pump     Air-to-water heat pump     


datacenter (1): www.wordscope.be (v4.0.br)

'Air-to-water heat pump' ->

Date index: 2021-09-26
w