Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Adjust tightness of pump components
Adjusting tightness of pump components
Adjustment of tightness of pump components
Adjustment of tightness of pump parts
Basal membrane dilution
DP
Diluting pump
Dilution air pump
Dye dilution pump
Dye-dilution cardiac output unit
Operate pumps for fire extinguishing
Pump
Pump items for storage
Pump product for storage
Pump products for storage
Pumping machinery
Pumping products for storage
Use pumps for fire extinguishing
Use pumps for putting out fires
Water pump
Work pumps for fire extinguishing

Traduction de «Diluting pump » (Anglais → Néerlandais) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous








adjusting tightness of pump components | adjustment of tightness of pump parts | adjust tightness of pump components | adjustment of tightness of pump components

spanning van pomponderdelen aanpassen


use pumps for putting out fires | work pumps for fire extinguishing | operate pumps for fire extinguishing | use pumps for fire extinguishing

brandbluspompen bedienen | brandbluspompen gebruiken


pump items for storage | pump product for storage | pump products for storage | pumping products for storage

pompproducten voor opslag




Dye-dilution cardiac output unit

eenheid voor meting van hartminuutvolume met behulp van kleurstofverdunning


TRADUCTIONS EN CONTEXTE
2.2.1. Determination of the Diluted Exhaust Gas Flow PDP-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust is kept within ± 6 K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x V0 x NP x (pB - p1 ) x273 / (101,3 x T) where M TOTW = mass of the diluted exhaust gas on wet basis over the cycle V0 = volume of gas pumped per revolution under test conditions (m³/rev) NP = total revolutions of pump per test pB = atmospheric pressure in the test cell (kPa) p1 = press ...[+++]

Bepaling van de verdunde uitlaatgasstroom PDP-CVS-systeem De massastroom gedurende de cyclus wordt als volgt berekend, indien de temperatuur van het verdunde uitlaatgas gedurende de cyclus met behulp van een warmtewisselaar binnen ± 6 K wordt gehouden: M TOTW = 1,293 * V0 * NP * (pB - p1 ) * 273 / (101,3 * T) waarin: M TOTW = massa van het verdunde uitlaatgas op natte basis gedurende de cyclus; V0 = gasvolume dat onder testomstandigheden per omwenteling wordt gepompt (m³/omw); NP = totaal aantal omwentelingen van de pomp per test; PB = luchtdruk in de beproevingsruimte (kPa); p1 = drukvermindering t.o.v. de luchtdruk aan de pompinlaa ...[+++]


DP dilution air pump (Figure 15) (full flow double dilution only) The dilution air pump shall be located so that the secondary dilution air is supplied at a temperature of 298 K (25°C) ± 5 K.

Verdunningsluchtpomp DP (figuur 15) (alleen bij volledige stroom/dubbele verdunning) De verdunningsluchtpomp moet zich op een zodanige plaats bevinden dat de secundaire verdunningslucht op een temperatuur van 298 K (25 °C) ± 5 K wordt toegevoerd.


The double dilution system includes all important parts of the particulate sampling system, like filter holders and sampling pump, and additionally some dilution features, like a dilution air supply and a secondary dilution tunnel.

Het dubbele verdunningssysteem omvat alle belangrijke onderdelen van het deeltjesbemonsteringssysteem, zoals filterhouders en bemonsteringspomp, en daarnaast een aantal verdunningskenmerken, zoals een verdunningsluchttoevoer en een secundaire verdunningstunnel.


PDP positive displacement pump The PDP meters total diluted exhaust flow from the number of the pump revolutions and the pump displacement.

Verdringerpomp PDP De PDP bepaalt de totale verdunde uitlaatgasstroom uit het aantal pompomwentelingen en de verplaatsing door de pomp.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: M TOTW ,i = 1,293 x V0 x NP,i x (pB - p1 ) x 273 / (101,3 x T) where NP,i = total revolutions of pump per time interval CFV-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust gas is kept within ± 11K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x t x Kv x pA / T where M TOTW = mass of the diluted exhaust gas on wet basis over the cycle t = cycle time (s) KV = cali ...[+++]

De momentane massa van het verdunde uitlaatgas wordt dan als volgt berekend: M TOTW ,i = 1,293 * V0 * NP,i * (pB - p1 ) * 273 / (101,3 x T) waarin: NP,i = totaal aantal omwentelingen van de pomp per tijdsinterval. CFV-CVS-systeem De massastroom gedurende de cyclus wordt als volgt berekend, indien de temperatuur van het verdunde uitlaatgas gedurende de cyclus met behulp van een warmtewisselaar binnen ± 11 K wordt gehouden: M TOTW = 1,293 * t * Kv * pA / T waarin: M TOTW = massa van het verdunde uitlaatgas op natte basis gedurende de cyclus; t = cyclusduur (s); K V = kalibreringscoëfficiënt van de kritische stroomventuri voor standaardom ...[+++]


4.2.2.7. a sampling probe S2, placed before the displacement pump and directed upstream of the flow of diluted gases to sample the mixture of diluted gases for the duration of the test at a constant rate of flow using, if necessary, a filter, a flow meter and a pump.

4.2.2.7. een sonde S2 boven de verdringerpomp die ten opzichte van de stroomverdunde gassen stroomopwaarts is gericht en die het mogelijk maakt door middel van een filter, een debietmeter en een pomp tijdens de duur van de proef met constant debiet een monster van het mengsel verdunde gassen te nemen.


4.4.6. The volume displaced at each complete rotation of pump P1 and the displacement value at the lowest possible pump speed, as recorded by the revolution counter, must make it possible to determine the overall volume of the mixture of exhaust gases and dilution air displaced by pump P1 during the test to within ± 2 %.

4.4.6. Het bij iedere volledige omwenteling van pomp P1 verplaatste volume en de waarde van de verplaatsing bij de kleinst mogelijke pompsnelheid, zoals geregistreerd door de totalisator CT, moeten het mogelijk maken het totale tijdens de proef door P1 verplaatste volume van het mengsel uitlaatgassen/verdunningslucht tot op ± 2 % nauwkeurig te bepalen.


The double dilution system includes all important parts of the particulate sampling system, like filter holders and sampling pump, and additionally some dilution features, like a dilution air supply and a secondary dilution tunnel.

Het dubbele verdunningssysteem omvat alle belangrijke onderdelen van het deeltjesbemonsteringssysteem, zoals filterhouders en bemonsteringspomp, en daarnaast een aantal verdunningskenmerken, zoals de verdunningsluchttoevoer en een secundaire verdunningstunnel.


4.2.2.7. a sampling probe S2, placed before the displacement pump and directed upstream of the flow of diluted gases to sample the mixture of diluted gases for the duration of the test at a constant rate of flow using, if necessary, a filter, a flow meter and a pump.

4.2.2.7. een sonde S2 boven de verdringerpomp die ten opzichte van de stroomverdunde gassen stroomopwaarts is gericht en die het mogelijk maakt door middel van een filter, een debietmeter en een pomp tijdens de duur van de proef met constant debiet een monster van het mengsel verdunde gassen te nemen.


The double dilution system includes all important parts of the particulate sampling system, like filter holders and sampling pump, and additionally some dilution features, like a dilution air supply and a secondary dilution tunnel.

Het dubbele verdunningssysteem omvat alle belangrijke onderdelen van het deeltjesbemonsteringssysteem, zoals filterhouders en bemonsteringspomp, en daarnaast een aantal verdunningskenmerken, zoals de verdunningsluchttoevoer en een secundaire verdunningstunnel.


w