Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Gas chromatograph with mass detector
Gas chromatograph without mass detector
Gas chromatograph-tandem mass spectrometer
Gas chromatograph-tandem mass spectrometry
Gas chromatography-tandem mass spectrometry

Traduction de «gas chromatograph without mass detector » (Anglais → Néerlandais) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
gas chromatograph without mass detector

gaschromatograaf zonder massaspectrometrie


gas chromatograph with mass detector

gaschromatograaf met massaspectrometrie


gas chromatograph-tandem mass spectrometer | gas chromatograph-tandem mass spectrometry | gas chromatography-tandem mass spectrometry

gaschromatografie-tandemmassaspectrometrie | GC-MS/MS [Abbr.]
TRADUCTIONS EN CONTEXTE
3.4. Gas chromatograph fitted with a flame spectrophotometer detector equipped with a selective filter for sulphur compounds (wavelength = 394 nm) or any other suitable detector.

3.4. Gaschromatograaf voorzien van een vlamfotometerdetector met zwavelfilter (λ = 394 nm) of van een andere hiervoor geschikte detector.


gas chromatograph with a flame ionisation detector and a split/splitless injector,

—gaschromatograaf voorzien van een vlamionisatiedetector en een split/splitless-injector,


gas chromatograph with a flame ionisation detector and a split/splitless injector,

Gaschromatograaf voorzien van een vlamionisatiedetector en een split/splitless-injector.


By application of a run by the gas chromatograph without injection of a fat solution and subsequent subtraction of the stored baseline rising of the baseline can be avoided.

Door de gaschromatograaf in werking te stellen zonder injectie van een vetoplossing gevolgd door aftrekken van de opgeslagen basislijn kan verhoging van de basislijn worden voorkomen.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
2.2.1. Determination of the Diluted Exhaust Gas Flow PDP-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust is kept within ± 6 K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x V0 x NP x (pB - p1 ) x273 / (101,3 x T) where M TOTW = mass of the diluted exhaust gas on wet basis over the cycle V0 = volume of gas pumped per revolution under test conditions (m³/rev) NP = total revolutions of pump per test pB = atmospheric pressure in the test cell (kPa) p1 = pressure drop below atmospheric at the pump inlet (kPa) T = average ...[+++]

Bepaling van de verdunde uitlaatgasstroom PDP-CVS-systeem De massastroom gedurende de cyclus wordt als volgt berekend, indien de temperatuur van het verdunde uitlaatgas gedurende de cyclus met behulp van een warmtewisselaar binnen ± 6 K wordt gehouden: M TOTW = 1,293 * V0 * NP * (pB - p1 ) * 273 / (101,3 * T) waarin: M TOTW = massa van het verdunde uitlaatgas op natte basis gedurende de cyclus; V0 = gasvolume dat onder testomstandigheden per omwenteling wordt gepompt (m³/omw); NP = totaal aantal omwentelingen van de pomp per test; PB = luchtdruk in de beproevingsruimte (kPa); p1 = drukvermindering t.o.v. de luchtdruk aan de pompinlaa ...[+++]


In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: M TOTW ,i = 1,293 x V0 x NP,i x (pB - p1 ) x 273 / (101,3 x T) where NP,i = total revolutions of pump per time interval CFV-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust gas is kept within ± 11K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x t x Kv x pA / T where M TOTW = mass of the diluted exhaust gas on wet basis over the cycle t = cycle time (s) KV = cali ...[+++]

De momentane massa van het verdunde uitlaatgas wordt dan als volgt berekend: M TOTW ,i = 1,293 * V0 * NP,i * (pB - p1 ) * 273 / (101,3 x T) waarin: NP,i = totaal aantal omwentelingen van de pomp per tijdsinterval. CFV-CVS-systeem De massastroom gedurende de cyclus wordt als volgt berekend, indien de temperatuur van het verdunde uitlaatgas gedurende de cyclus met behulp van een warmtewisselaar binnen ± 11 K wordt gehouden: M TOTW = 1,293 * t * Kv * pA / T waarin: M TOTW = massa van het verdunde uitlaatgas op natte basis gedurende de cyclus; t = cyclusduur (s); K V = kalibreringscoëfficiënt van de kritische stroomventuri voor standaardom ...[+++]


5.1. High temperature gas chromatograph suited for temperatures of at least 400 - 450 °C, equipped with a flame ionization detector (FID) and constant mass flow controller for the carrier gas.

5.1. Gaschromatograaf geschikt voor hoge temperaturen van minstens 400-450 °C, uitgerust met een vlamionisatiedetector (VID) en constante massastroomregelaar voor het draaggas.


3.4. Gas chromatograph fitted with a flame spectrophotometer detector equipped with a selective filter for sulphur compounds (wavelength = 394 nm) or any other suitable detector.

3.4. Gaschromatograaf voorzien van een vlamfotometerdetector met zwavelfilter (l = 394 nm)


GAS CHROMATOGRAPH WITH ELECTRON DETECTOR, NI 63 .

GASCHROMATOGRAAF, UITGERUST MET EEN ELECTRON-CAPTURE DETECTOR, NI 63 .


// Gas chromatograph with electron detector, Ni 63.

// Gaschromatograaf, uitgerust met een Electron-Capture Detector, Ni 63.




datacenter (1): www.wordscope.be (v4.0.br)

'gas chromatograph without mass detector' ->

Date index: 2021-06-04
w