If measurements are made using the method described in Annex VII, the radiation reference limits shall be 64 to 54 dB microvolts/m (1 600 to 500 microvolts/m) in the 30 to 75 MHz frequency band, this limit decreasing logarithmically (linearly) with frequencies above 30 MHz, and 54 to 65 dB microvolts/m (500 to 1 800 microvolts/m) in the 75 to 400 MHz band, this limit increasing logarithmically (linearly) with frequencies above 75 MHz as shown in Appendix 5 to this Annex.
Bij de meting van de straling volgens de methode van bijlage VII bedraagt de stralingsreferentiegrens 64-54 dBµV/m (1 600-500 µV/m) in de frequentieband 30-75 MHz, waarbij deze grenswaarde logaritmisch (lineair) afneemt met de frequentie, en 54-65 dBµV/m (500-1 800 µV/m) in de frequentieband 75-400 MHz, waarbij deze grenswaarde logaritmisch (lineair) toeneemt met de frequentie, zoals is aangegeven in aanhangsel 5.