Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Alternate tank
Aux fuel tank
Auxiliary fuel tank
Centerline external aircraft fuel tank
Centerline external fuel tank
Centerline external tank
Cylindrical external fuel tank
External fuel tank
External fuel tank fuel quantity transmitter
External fuel tanks transfer test
External tank
Fuel tank quantity test switch
Rear fuel transfer tank

Traduction de «External fuel tanks transfer test » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
external fuel tanks transfer test

contrôle de transfert des réservoirs supplémentaires


external tank (1) | external fuel tank (2) | alternate tank (3) | auxiliary fuel tank (4) [ aux fuel tank ]

réservoir supplémentaire (1) | réservoir supplémentaire à carburant (2) | réservoir auxiliaire (3)


centerline external aircraft fuel tank | centerline external fuel tank | centerline external tank

réservoir supplémentaire central


external fuel tank refuel/transfer check valve

clapet antiretour d'avitaillement et de transfert carburant des réservoirs extérieurs


external fuel tank fuel quantity transmitter

transmetteur de quantité carburant de réservoir extérieur


cylindrical external fuel tank

réservoir de carburant extérieur cylindrique


fuel tank quantity test switch

poussoir d'essai quantité carburant réservoir


rear fuel transfer tank

réservoir arrière d'équilibrage
TRADUCTIONS EN CONTEXTE
Static thermoplastic tanks for above ground storage of domestic heating oils, kerosene and diesel fuels — Blow moulded and rotationally moulded polyethylene tanks and rotationally moulded tanks made of anionically polymerized polyamide 6 — Requirements and test methods

Réservoirs statiques en thermoplastiques destinés au stockage non enterré de fioul domestique de chauffage, de pétrole lampant et de gazole — Réservoirs en polyéthylène moulés par soufflage et par rotation et réservoirs moulés par rotation fabriqués en polyamide 6 polymérisé de manière anionique — Exigences et méthodes d’essai


2.2.1. The inlet orifice of the petrol or ethanol tank shall be designed so that it prevents the tank from being filled from a fuel pump delivery nozzle that has an external diameter of 23,6 mm or greater.

2.2.1. L’orifice de remplissage du réservoir d’essence ou d’éthanol est conçu de manière à empêcher le remplissage avec un pistolet distributeur de carburant dont l’embouchure a un diamètre extérieur égal ou supérieur à 23,6 mm.


(h) a fuel tank having a capacity exceeding 114 L shall be tested hydrostatically on completion to a head of at least 2.44 m above the crown or to the maximum head to which the tank will be subjected, whichever is the greater, such tests shall be witnessed by an inspector, but in the case of any tank of a capacity not exceeding 1 364 L the inspector may, when it is not practicable for him to witness the test, accept a written statement from the manufacturer certifying that the hydrostatic test ...[+++]

h) si elle a une capacité de plus de 114 L elle sera éprouvée, après achèvement de la construction, sous une charge hydrostatique d’au moins 2,44 m au-dessus du plafond ou sous la charge maximum qu’elle devra supporter, si cette seconde charge est plus grande; ces épreuves seront effectuées en présence de l’inspecteur, mais dans le cas de toute soute d’une capacité d’au plus 1 364 L, l’inspecteur pourra, s’il lui est impossible d’assister à l’épreuve, accepter du fabricant un rapport écrit certifiant que l’épreuve hydrostatique décri ...[+++]


(2) A fuel tank that is not separate from the hull of a fishing vessel shall be considered as part of the hull, taking into consideration the strength requirements of the vessel and the possibility of contamination of oil fuel with water, but the standards of construction and testing shall not be less than those set out in this section for a fuel tank that is separate from the hull.

(2) Une soute à combustible qui n’est pas séparée de la coque d’un bateau de pêche sera censée faire partie de la coque, compte tenu de la résistance que devra offrir le bateau et de la possibilité de contamination du mazout par l’eau; toutefois, les normes de construction et d’épreuve ne seront pas inférieures à celles qui sont données au présent article pour une soute à combustible distincte de la coque.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(14) Fuel tanks that are not separate from the hull shall be considered as part of the hull, taking into consideration the strength requirements of the vessel and the possibility of contamination of oil fuel with water, but the standards of construction and testing shall not be less than those given in this section for fuel tanks that are separate from the hull.

(14) Les soutes à combustible non distinctes de la coque seront censées faire partie de la coque, compte tenu de la résistance que devra offrir le bateau de pêche et de la possibilité de contamination du mazout par de l’eau; toutefois, les normes de construction et d’épreuve ne seront pas inférieures à celles qui sont données au présent article pour les soutes à combustible distinctes de la coque.


(b) deep tanks and peak tanks used for carrying water, and deep tanks and double bottom tanks arranged for carrying oil fuel shall be tested to a head of water equal to the maximum head to which the tanks can be subjected in service, but not less than 2.44 m above the crown of the tanks where the moulded depth to the strength deck exceeds 4.88 m, and 915 mm where the moulded depth does not exceed 3.05 m; intermediate heads may be obtained by interpolation between 4.88 and 3.05 m;

b) les cales à eau et les coquerons devant servir au transport de l’eau ainsi que les cales à eau et les doubles-fonds aménagés pour le transport du mazout seront éprouvés sous une charge d’eau égale à la charge maximum à laquelle ils pourront être soumis en service mais atteignant au moins 2,44 m au-dessus de leur sommet lorsque le creux sur quille jusqu’au pont de résistance dépasse 4,88 m et au moins 915 mm lorsque le creux sur quille ne dépasse pas 3,05 m; les charges intermédiaires s’obtiennent par interpolation entre 4,88 m et 3,05 m;


Are you aware that the costing provided to the Canadian government from PMA-265 at the meetings Boeing was part of did not include many components: external fuel tanks, pylons, targeting pods, missile launchers, radio warning receivers, jammers, chaff/flares, and the gun?

Savez-vous que le prix communiqué au gouvernement du Canada par PMA-265, lors des rencontres avec Boeing, ne comprenait pas un grand nombre de composantes, comme les réservoirs de carburant externes, les mats, les nacelles de désignation d'objectif, les paniers lance-missiles, les récepteurs d'avertissement radioélectrique, les brouilleurs, les lance-leurres et le canon?


A possible cost-effective evaporative fuel tank and fuel supply permeation testing will be assessed in this study as an alternative to the SHED test for the sub category vehicles which were not subject yet to evaporative emission testing, refer to Article 23(4) and (5).

Cette même étude examinera également la possibilité et le rapport coût/efficacité de remplacer l'essai SHED par un essai de perméation du réservoir et du circuit de carburant pour les sous-catégories de véhicules qui ne sont pas encore soumises à des essais concernant les émissions par évaporation (voir l'article 23, paragraphes 4 et 5).


6. Basing itself on the results of the environmental effect study, the Commission shall adopt a delegated act in accordance with Article 75 determining which of the (sub-)categories L1e-A, L1e-B, L2e, L5e-B, L6e-B, L7e-B and L7e-C for the Euro 5 level are to be subject to SHED testing or to fuel tank and tubing permeation testing, with the test limits listed in Annex VI (C2).

6. En se fondant sur les conclusions de l'étude d'incidence environnementale, la Commission adopte un acte délégué conformément à l'article 75 déterminant quelles (sous-)catégories parmi les (sous-)catégories L1e-A, L1e-B, L2e, L5e-B, L6e-B, L7e-B et L7e-C pour le niveau Euro 5 doivent être soumises à l'essai SHED ou aux essais de perméation du réservoir et du circuit de carburant, en tenant compte des valeurs limites fixées à l'annexe VI, section C2.


For example, “check compliance of the location of the fuel tank in a vehicle with the provisions of point 5.10 of Annex I to Directive 70/221/EEC” has to be understood as part of “to carry out test”.

L’expression “procéder à des essais” couvre, par exemple, une phrase comme “vérifier la conformité de l’emplacement du réservoir à carburant dans le véhicule avec les dispositions du point 5.10 de l’annexe I de la directive 70/221/CEE”.




datacenter (1): www.wordscope.be (v4.0.br)

'External fuel tanks transfer test' ->

Date index: 2024-11-01
w