Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Buried drain
Burner pipe
Covered drain
Cut copper gas-line piping
Cut copper pipes to size
Drain pipe
Drain tile
Field drain
Field drain pipe
Fire brigade
Fire endurance rating
Fire piping
Fire protection piping system
Fire protection piping system installer
Fire protection rating
Fire protection system
Fire resistance rating
Fire resistant degree
Fire-resistance rate
Fire-resistance rating
Fire-resistive rating
Firing pipe
Industrial fire brigade
Land pipe
Lateral drain
Plant fire brigade
Preparation of copper pipe gas-lines
Prepare copper pipes for use as gas lines
Private fire brigade
Private fire department
Private fire fighting force
Private fire piping
Private fire protection system
Private piping for fire use
Subsoil pipe
Subsurface drain
Underdrain

Vertaling van "Fire piping " (Engels → Frans) :

TERMINOLOGIE
private fire piping | private fire protection system | private piping for fire use

secours particuliers contre l'incendie




fire protection system | fire piping

seau d'eau d'incendie | réseau d'eau-incendie | réseau d'incendie


fire protection piping system installer

monteur de tuyauterie d'eau contre les incendies [ monteuse de tuyauterie d'eau contre les incendies ]


piping for the distribution of the fire-extinguishing medium

tuyautage de répartition de l'agent d'extinction


buried drain | covered drain | drain pipe | drain tile | field drain | field drain pipe | land pipe | lateral drain | subsoil pipe | subsurface drain | underdrain

drain | drain souterrain | tuyau de drainage


cut copper gas-line piping | preparation of copper pipe gas-lines | cut copper pipes to size | prepare copper pipes for use as gas lines

préparer des conduites de cuivre pour le gaz




fire endurance rating [ fire protection rating | fire resistance rating | fire-resistance rating | fire-resistive rating | fire resistant degree | fire-resistance rate ]

degré de résistance au feu [ indice de résistance au feu | degré pare-flammes | durée de résistance au feu | durée de stabilité au feu | taux de résistance au feu | cote de résistance au feu ]


industrial fire brigade | private fire department | private fire brigade | plant fire brigade | private fire fighting force | fire brigade

corps de sapeurs-pompiers industriel
IN-CONTEXT TRANSLATIONS
(4) In every Class B ship over 22.9 m in length carrying more than 12 passengers, at least one of the power fire pumps shall be fitted with an automatic control whereby full pressure will be maintained on the fire mains at all times while passengers are on board excepting that where piping is liable to frost damage such piping may be maintained in a drained condition provided the shut-off valve and drainage cocks are located in a readily accessible location with a pressure gauge being installed on the drainable section of the piping i ...[+++]

(4) Sur tout navire de la classe B long de plus de 22,9 m et transportant plus de 12 passagers, au moins l’une des pompes d’incendie mécaniques aura une commande automatique permettant de maintenir en tout temps la pression dans les collecteurs pendant que des passagers seront à bord, mais si le gel risque d’endommager certains tronçons des conduites, ces tronçons peuvent être vidangés et demeurer dans cet état, à condition que la soupape d’arrêt et les robinets de vidange soient situés en un endroit facilement accessible et qu’un manomètre soit installé sur les tronçons vidangeables des conduites, juste à côté de la soupape d’arrêt.


33 (1) Every Class A ship shall be provided with water pipes and hydrants; the diameter of the water pipes shall be sufficient to enable an adequate supply of water to be provided for the simultaneous operation of at least two fire hoses and for the projection thereby of two powerful jets of water; the number and position of the hydrants shall be such that at least two such jets may be directed into any part of the ship by means of two fire hoses each not over 18 m in length, each jet being supplied from a separate hydrant; at leas ...[+++]

33 (1) Tout navire de la classe A aura des tuyaux d’eau et des bouches d’incendie. Le diamètre des tuyaux d’eau sera suffisant pour assurer un débit permettant l’utilisation simultanée d’au moins deux manches d’incendie pour projeter deux jets d’eau énergiques; le nombre et l’emplacement des bouches d’incendie devront permettre de diriger au moins deux de ces jets dans une partie quelconque du navire au moyen de deux manches d’incendie d’une longueur respective d’au plus 18 m, chacun de ces jets provenant d’une bouche distincte; il y aura au moins une manche par bouche d’incendie.


(v) the firefighting system, including pump drives and fuel supply lines, fire pumps and associated piping, fire hydrants, fire hoses and nozzles;

(v) le système d’extinction d’incendie, notamment les mécanismes d’entraînement des pompes et les canalisations d’alimentation en carburant et les pompes à incendie et les canalisations connexes, ainsi que les bouches d’incendie et les tuyaux et lances à incendie;


(5) The arrangements for distributing foam in connection with oil-fired boilers and oil fuel units, shall be such that it can be directed at will either onto the tank top beneath the boiler by means of the fixed distribution pipes, or by hose and nozzle to such places above the floor plates as boiler fronts and oil fuel units; the distribution pipes shall be of steel, galvanized inside and outside.

(5) En ce qui concerne les chaudières chauffées au mazout et les appareils à mazout, il devra être possible de diriger la mousse soit, au moyen de tuyaux de distribution fixes, sur le plafond de ballast sous les chaudières, soit, au moyen d’une manche et d’un ajutage, sur certains points situés au-dessus des tôles de parquet, par exemple les façades de chaudière et les appareils à mazout; les tuyaux de distribution seront en acier, galvanisés tant à l’intérieur qu’à l’extérieur.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(f) escape valves shall be provided in connection with every fire pump and shall be so placed and adjusted as to prevent excessive pressure in any part of the water pipes served by the pump; such escape valves need not be fitted where the pumps are of the centrifugal type and the inspector is satisfied that the water service pipes are adequate for the maximum pressure that the pumps can develop;

f) toute pompe d’incendie sera munie de soupapes de sûreté, placées et réglées de façon à empêcher toute surélévation de pression en tout point des tuyaux d’eau qu’elle alimente; ces soupapes de sûreté n’auront pas à être posées si les pompes sont centrifuges et si l’inspecteur a la certitude que les tuyaux du service d’eau peuvent résister à la pression maximum que les pompes peuvent produire;


(a) Insecure tank or pipes, creating particular risk of fire.

(a) Mauvaise fixation du réservoir ou des conduites de carburant, posant un risque particulier d'incendie .


The title of Table 1 is replaced by ‘CLASSES OF REACTION-TO-FIRE PERFORMANCE FOR CONSTRUCTION PRODUCTS EXCLUDING FLOORINGS, LINEAR PIPE THERMAL INSULATION PRODUCTS, AND ELECTRIC CABLES’.

Le titre du tableau 1 est remplacé par le texte «CLASSIFICATION DES CARACTÉRISTIQUES DE RÉACTION AU FEU DES PRODUITS DE CONSTRUCTION, À L'EXCEPTION DES REVÊTEMENTS DE SOLS, DES PRODUITS LINEAIRÉS D'ISOLATION THERMIQUE DE TUYAUTERIE ET DES CÂBLES ÉLECTRIQUES».


For example, they relate to the location and identification of containers and pipes, fire-fighting equipment, certain traffic routes, illuminated and acoustic signs, as well as the introduction of appropriate verbal communications and hand signals.

Il s’agit par exemple de la localisation et de l’identification des récipients et tuyauteries, des matériels et équipements de lutte contre l’incendie, de certaines voies de circulation, des signaux lumineux et acoustiques, ainsi que l’institution d’une communication verbale et de signaux gestuels adéquats.


However, a non-potable water supply is authorized in exceptional cases for steam production, fire fighting and the cooling of refrigeration equipment, provided that the pipes installed for this purpose preclude the use of this water for other purposes and present no risk of contamination of meat.

Toutefois, à titre exceptionnel, une installation fournissant de l'eau non potable est autorisée pour la production de vapeur, la lutte contre les incendies et le refroidissement des équipements frigorifiques, à condition que les conduites installées à cet effet ne permettent pas l'utilisation de cette eau à d'autres fins et ne présentent aucun risque de contamination des viandes.


7.03.5. A fire-fighting system using water under pressure and comprising piping fed by one or more pumps serving nozzles through hydrants and hoses may be installed subject to the following conditions: (a) the fire pumps must be powered.

7.03.5. Une installation d'extinction par eau sous pression comprenant un tuyautage alimenté par une ou plusieurs pompes et desservant des lances par l'intermédiaire de bouches et de manches peut être mise en place dans les conditions suivantes: a) les pompes d'incendie sont entraînées par moteur.


w