Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Alfvén-wave instability
Circular woven hose
Fire department connection
Fire department standpipe outlet
Fire hose
Fire hose cabinet
Fire hose cart
Fire hose connection
Fire hose station
Fire-hose instability
Hose
Hose cabinet
Hose carrier
Hose cart
Hose connection
Hose station
Standpipe fire-hose outlet
Standpipe hose outlet
Standpipe outlet
Woven hose
Woven jacket fire hose
Woven jacket hose

Vertaling van "fire hoses shall " (Engels → Frans) :

TERMINOLOGIE
fire hose cabinet | fire hose station | hose cabinet | hose station

robinet d'incendie armé | poste d'incendie armé


woven hose [ circular woven hose | woven jacket hose | woven jacket fire hose ]

tuyau tissé [ tuyau d'incendie à renfort de toile ]


standpipe hose outlet [ standpipe outlet | fire department standpipe outlet | standpipe fire-hose outlet ]

prise de refoulement [ orifice de refoulement | prise intermédiaire ]


fire department connection [ hose connection | fire hose connection ]

prise d'incendie [ prise d'eau d'incendie ]




hose carrier | hose cart | fire hose cart

dévidoir mobile


hose cabinet | fire hose cabinet

armoire d'incendie | cabinet d'incendie




Alfvén-wave instability | fire-hose instability

instabilité lance d'incendie | instabilité à saccades | instabilité d'onde d'Alfvén
IN-CONTEXT TRANSLATIONS
(a) fire hoses shall be rigged and fire pumps operated to produce the required jets of water, and where an emergency pump is provided and the generator that supplies the power is situated above the bulkhead deck, the generator shall be started up and the pump shall be operated to produce the jets of water without anyone having to enter the machinery space;

a) les manches d’incendie seront montées, les pompes d’incendie seront mises en marche afin de produire les jets d’eau exigés, et s’il existe une pompe de secours alimentée par une génératrice située au-dessus du pont de cloisonnement, la génératrice sera mise en route et la pompe en marche afin de produire les jets d’eau sans que personne n’ait à pénétrer dans la tranche des machines;


(d) fire hoses shall be of one standard size in any ship to fit the hydrants, but machinery space hoses may be smaller in diameter for convenient handling;

d) les manches d’incendie d’un même navire devront avoir la même dimension standard et pouvoir s’adapter aux bouches d’incendie, mais les manches de la tranche des machines pourront avoir un diamètre plus petit pour faciliter la manutention;


(h) fire hoses shall have an internal diameter of not less than 38 mm and shall be in lengths of not more than 18.3 m; they shall be made of seamless hemp, closely woven flax canvas, rubber or other material that, in the opinion of the Board, is suitable for the purpose; they shall be fitted with couplings, conductors, valve keys and other necessary fittings, and shall be located in conspicuous positions;

h) les manches d’incendie auront un diamètre intérieur d’au moins 38 mm et seront en sections d’au plus 18,3 m; elles seront en tissu de chanvre sans coutures, en toile de lin de texture serrée, en caoutchouc ou en une autre matière que le Bureau jugera appropriée; elles seront munies des raccords, manchons, clefs à soupape et autres accessoires nécessaires et seront placées en évidence;


33 (1) Every Class A ship shall be provided with water pipes and hydrants; the diameter of the water pipes shall be sufficient to enable an adequate supply of water to be provided for the simultaneous operation of at least two fire hoses and for the projection thereby of two powerful jets of water; the number and position of the hydrants shall be such that at least two such jets may be directed into any part of the ship by means of two fire hoses each not over 18 m in length, each jet being ...[+++]

33 (1) Tout navire de la classe A aura des tuyaux d’eau et des bouches d’incendie. Le diamètre des tuyaux d’eau sera suffisant pour assurer un débit permettant l’utilisation simultanée d’au moins deux manches d’incendie pour projeter deux jets d’eau énergiques; le nombre et l’emplacement des bouches d’incendie devront permettre de diriger au moins deux de ces jets dans une partie quelconque du navire au moyen de deux manches d’incendie d’une longueur respective d’au plus 18 m, chacun de ces jets provenant d’une bouche distincte; il y aura au moins une manche par bouche d’incendie.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
61 (1) Every Class G ship shall be provided with appliances whereby at least two powerful jets of water can be rapidly and simultaneously directed into any part of the ship, at least one of which shall be from a single length of hose; such appliances shall include at least two pumps operated by power, and at least three fire hoses; in any case, at least one fire hose shall be provided for every 30 m in length of the ship or fraction thereof.

61 (1) Tout navire de la classe G aura des installations permettant de diriger rapidement et simultanément dans chacune de ses parties au moins deux jets d’eau énergiques dont au moins l’un proviendra d’une manche d’une seule pièce; ces installations comprendront au moins deux pompes mécaniques et au moins trois manches d’incendie. Dans tous les cas, il y aura au moins une manche d’incendie par 30 m de longueur du navire ou par fraction de ce chiffre.