Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
AMS
AMS technique
Accelerator mass spectrometry
Accelerator mass spectrometry technique
Airborne gamma spectrometry
Airborne-gamma-spectrometry
American Society for Mass Spectrometry
Analysis using spectrometry
Analytical spectrometry
Atomic mass spectrometry
Atomic spectrometry
EPR
EPR spectrometry
EPR spectroscopy
ESR
ESR spectroscopy
Electron paramagnetic resonance
Electron paramagnetic resonance spectrometry
Electron paramagnetic resonance spectroscopy
Electron spin resonance
Electron spin resonance spectrometry
Electron spin resonance spectroscopy
Emission spectrometry
HEIS spectrometry
HEISS
High-energy ion-scattering spectrometry
ICP
ICP-AES
ICP-OES
ICP-atomic emission spectrometry
ICP-optical emission spectrometry
Mass spectrometry
Molecular spectrometry
Optical spectrometry
RBS
Rutherford backscattering
Rutherford backscattering spectrometry
Rutherford backscattering spectroscopy
Spectrography
Spectrometry
Spectrophotometry
Spectroscopic analysis
Spectroscopy
Typology of mass spectrometry

Vertaling van "spectrometry " (Engels → Frans) :

TERMINOLOGIE
spectrometry [ atomic spectrometry | emission spectrometry | mass spectrometry | molecular spectrometry | optical spectrometry | spectrography | spectrophotometry | spectroscopic analysis | Spectroscopy(ECLAS) ]

spectrométrie [ analyse spectroscopique | spectrographie | spectrométrie atomique | spectrométrie d'émission | spectrométrie de masse | spectrométrie moléculaire | spectrométrie optique | spectrophotométrie ]


inductively coupled plasma-atomic emission spectrometry | ICP-AES | inductively coupled plasma-optical emission spectrometry | ICP-OES | ICP-atomic emission spectrometry | ICP-optical emission spectrometry

spectrométrie d'émission atomique à plasma à couplage inductif | spectrométrie d'émission atomique à plasma induit par haute fréquence | spectrométrie d'émission optique à plasma à couplage inductif | spectrométrie d'émission optique à plasma induit par haute fréquence | spectrométrie d'émission ICP-AES | spectrométrie d'émission ICP-OES


analysis using spectrometry | analytical spectrometry | mass spectrometry | typology of mass spectrometry

spectrométrie de masse


Rutherford backscattering spectrometry | RBS | Rutherford backscattering spectroscopy | Rutherford backscattering | high-energy ion-scattering spectrometry | HEISS | HEIS spectrometry

spectrométrie de rétrodiffusion de Rutherford | spectrométrie de rétrodiffusion Rutherford | spectroscopie de rétrodiffusion de Rutherford | spectroscopie de rétrodiffusion Rutherford | rétrodiffusion de Rutherford | rétrodiffusion Rutherford | spectrométrie des ions rétrodiffusés


electron paramagnetic resonance spectroscopy | EPR spectroscopy | electron spin resonance spectroscopy | ESR spectroscopy | electron paramagnetic resonance spectrometry | EPR spectrometry | electron spin resonance spectrometry | electron paramagnetic resonance | EPR | electron spin resonance | ESR

spectroscopie de résonance paramagnétique électronique | spectroscopie RPE | spectroscopie de résonance de spin électronique | spectroscopie RSE | spectrométrie de résonance paramagnétique électronique | spectrométrie RPE | spectrométrie de résonance de spin électronique | spectrométrie RSE | résonance paramagnétique électronique | RPE | résonance de spin électronique | RSE


airborne gamma spectrometry [ airborne-gamma-spectrometry ]

spectrométrie gamma aéroportée


accelerator mass spectrometry | atomic mass spectrometry [ AMS ]

spectrométrie de masse par accélérateur


inductively coupled plasma atomic emission spectrometry | inductively coupled plasma atomic emission spectroscopy | inductively coupled plasma optical emission spectrometry | ICP [Abbr.] | ICP-AES [Abbr.] | ICP-OES [Abbr.]

spectrométrie d’émission atomique à plasma à couplage inductif | ICP-AES [Abbr.]


AMS technique [ accelerator mass spectrometry technique ]

technique SMA [ technique de spectrométrie de masse par accélérateur ]


American Society for Mass Spectrometry

American Society for Mass Spectrometry
IN-CONTEXT TRANSLATIONS
Part 1: Cold-vapour atomic absorption spectrometry (CV-AAS) and Part 2: Cold-vapour atomic fluorescence spectrometry (CV-AFS.)

Partie 1: Spectrométrie d'absorption atomique en vapeur froide (SAA-VP) et partie 2: spectrométrie de fluorescence atomique en vapeur froide (SFA-VP).


The method of analysis to be used for monitoring is preferably high performance liquid chromatography — mass spectrometry/(mass spectrometry) (HPLC-MS/(MS)) or, if HPLC-MS/(MS) is not possible, gas chromatography — mass spectrometry (GC-MS).

La méthode d'analyse à utiliser pour le suivi est de préférence la chromatographie en phase liquide à haute performance couplée à la spectrométrie de masse (ou spectrométrie de masse en tandem) [CLHP-SM/(SM)] ou, si la CLHP-SM/(SM) n'est pas possible, la chromatographie en phase gazeuse couplée à la spectrométrie de masse (CG-SM).


Assessment and verification: the applicant shall either provide a declaration of non-use or a test report using the following test methods: direct determination by Atomic Absorption Spectrometry or Inductively Coupled Plasma (ICP) Mass Spectrometry.

Évaluation et vérification: le demandeur doit fournir une déclaration de non-utilisation ou un rapport d'essai établi à l'aide des méthodes suivantes: détermination directe par spectrométrie d'absorption atomique ou par spectrométrie de masse à plasma à couplage inductif (ICP-MS).


physicochemical test (e.g. Gas chromatography-Mass spectrometry/Mass spectrometry (GC-MS/MS) or Gas chromatography/Low resolution mass spectrometry (GC/LRMS)) where the measured method precision characteristics do not meet the requirements for quantitative tests.

essai physico-chimique [chromatographie en phase gazeuse-spectrométrie de masse/spectrométrie de masse (CG-SM/SM) ou chromatographie en phase gazeuse/spectrométrie de masse basse résolution (CG/SMBR)], pour lequel les caractéristiques de la précision de la méthode établies ne remplissent pas les prescriptions applicables aux essais quantitatifs.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
A series of methods, such as high-performance liquid chromatography (HPLC) with fluorimetric detection, liquid chromatography (LC), mass spectrometry (MS), immunoassays and functional assays, such as the phosphatase inhibition assay, shall be used as alternatives or supplementary to the biological testing methods, provided that either alone or combined they can detect at least the following analogues, that they are not less effective than the biological methods and that their implementation provides an equivalent level of public health protection:

Une série de méthodes telles que la chromatographie liquide haute performance (CLHP) avec détection fluorimétrique, la chromatographie liquide (CL), la spectrométrie de masse (SM), les immuno-essais et les tests fonctionnels, tels que le test d'inhibition de la phosphatase, peuvent être utilisées en lieu et place des méthodes biologiques ou les compléter, sous réserve que, seules ou combinées, elles permettent de détecter au moins les analogues ci-après, elles ne soient pas moins efficaces que les méthodes biologiques et que leur mise en œuvre assure un degré équivalent de protection de la santé publique:


The reference method for the measurement of arsenic, cadmium and nickel concentrations in ambient air is currently being standardised by CEN and shall be based on manual PM sampling equivalent to EN 12341, followed by digestion of the samples and analysis by Atomic Absorption Spectrometry or ICP Mass Spectrometry.

La méthode de référence pour la mesure des concentrations d'arsenic, de cadmium et de nickel dans l'air ambiant est en voie de normalisation par le CEN et sera basée sur un échantillonnage manuel de la fraction PM équivalent à la norme EN 12341, suivi de la digestion des échantillons et de leur analyse par spectrométrie d'absorption atomique ou spectrométrie de masse à plasma inductif.


The reference method for the measurement of total gaseous mercury concentrations in ambient air shall be an automated method based on Atomic Absorption Spectrometry or Atomic Fluorescence Spectrometry.

La méthode de référence pour la mesure des concentrations totales de mercure gazeux dans l'air ambiant est une méthode automatisée basée sur la spectrométrie d'absorption atomique ou la spectrométrie de fluorescence atomique.


The reference method for the measurement of total gaseous mercury concentrations in ambient air shall be an automated method based on Atomic Absorption Spectrometry or Atomic Fluorescence Spectrometry.

La méthode de référence pour la mesure des concentrations totales de mercure gazeux dans l'air ambiant est une méthode automatisée basée sur la spectrométrie d'absorption atomique ou la spectrométrie de fluorescence atomique.


The reference method for the measurement of arsenic, cadmium and nickel concentrations in ambient air is currently being standardised by CEN and shall be based on manual PM10 sampling equivalent to EN 12341, followed by digestion of the samples and analysis by Atomic Absorption Spectrometry or ICP Mass Spectrometry.

La méthode de référence pour la mesure des concentrations d'arsenic, de cadmium et de nickel dans l'air ambiant est en voie de normalisation par le CEN et sera basée sur un échantillonnage manuel de la fraction PM10 équivalent à la norme EN 12341, suivi de la digestion des échantillons et de leur analyse par spectrométrie d'absorption atomique ou spectrométrie de masse à plasma inductif.


8.2. The use of inductively-coupled plasma - optical emission spectrometry is permitted as an alternative to flame atomic absorption spectrometry.

8.2. L'utilisation de la spectrométrie à plasma à couplage inductif est autorisée en remplacement de la spectrométrie d'absorption atomique à flamme.


w