Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Adjust voltage
Adjusting voltage
Arrange rental car drop-off
Change voltage
Constant-voltage transformer
D.c.forward-voltage-drop test
DC forward-voltage-drop test
Direct current forward-voltage-drop test
Drop hammer brands
Drop hammer models
Drop hammer types
Drop hammer varieties
Drop in prices
Electrical high-voltage probe
Electrostatic voltage detector
Fall in prices
Loss in voltage
Position rental car drop-off
Potential drop
Prepare rental car drop-off
Price decrease
Price reduction
Reduction of prices
Sort rental car drop-off
Voltage changing
Voltage decrease
Voltage drop
Voltage drop or rise for a specified load condition
Voltage reduction
Voltage regulation for a specified load condition

Traduction de «voltage drop » (Anglais → Néerlandais) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
voltage drop or rise for a specified load condition | voltage regulation for a specified load condition

spanningsdaling bij een bepaalde belastingstoestand | spanningsverhoging bij een bepaalde belastingstoestand


d.c.forward-voltage-drop test | DC forward-voltage-drop test | direct current forward-voltage-drop test

meting van de voorwaartse gelijkspanningsval


loss in voltage | potential drop | voltage decrease | voltage drop | voltage reduction

potentiaalval | potentiaalverval | spanningdaling | spanningsdaling | spanningsval | spanningsverlaging | spanningsverlies | spanningsverval | spanningval | spanningverlies | spanningverval


position rental car drop-off | prepare rental car drop-off | arrange rental car drop-off | sort rental car drop-off

aflevering van huurauto's regelen | aflevering van huurwagens regelen


drop hammer brands | drop hammer varieties | drop hammer models | drop hammer types

soorten valhamers


adjusting voltage | change voltage | adjust voltage | voltage changing

voltage afstellen


Electrical high-voltage probe

sonde voor elektrische hoogspanning


Electrostatic voltage detector

detector voor elektrostatische spanning


Constant-voltage transformer

transformator voor constante spanning


price reduction [ drop in prices | fall in prices | price decrease | reduction of prices ]

prijsdaling [ prijsinzinking | prijsvermindering ]
TRADUCTIONS EN CONTEXTE
continue to work correctly or resume its correct functioning without loss of data available before the voltage drop if the voltage drop is temporary, i.e. due to restarting the engine;

correct te blijven functioneren, of zijn correct functioneren te hervatten zonder verlies van de data die voor de spanningsdaling aanwezig waren, indien de spanningsdaling tijdelijk is, dat wil zeggen ten gevolge van het opnieuw starten van de motor;


continue to work correctly or resume its correct functioning without loss of data available before the voltage drop if the voltage drop is temporary, i.e. due to restarting the engine;

correct te blijven functioneren, of zijn correct functioneren te hervatten zonder verlies van de data die voor de spanningsdaling aanwezig waren, indien de spanningsdaling tijdelijk is, dat wil zeggen ten gevolge van het opnieuw starten van de motor;


abort an existing measurement and return to the position ‘For Hire’ if the voltage drop is for a longer period.

een bestaande meting af te breken en naar de stand „Vrij” terug te keren indien de spanningsdaling gedurende een langere periode optreedt.


Instruments operated from battery power shall indicate whenever the voltage drops below the minimum required value and shall under those circumstances either continue to function correctly or be automatically put out of service.

Werktuigen met batterijvoeding moeten steeds aangeven wanneer de spanning beneden de vereiste minimumwaarde daalt en moeten onder die omstandigheden correct blijven functioneren of automatisch worden uitgeschakeld.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
Instruments operated from battery power shall indicate whenever the voltage drops below the minimum required value and shall under those circumstances either continue to function correctly or be automatically put out of service.

Werktuigen met batterijvoeding moeten steeds aangeven wanneer de spanning beneden de vereiste minimumwaarde daalt en moeten onder die omstandigheden correct blijven functioneren of automatisch worden uitgeschakeld.


The electric drive train shall be supplied from a DC voltage source with a maximum voltage drop of 5 per cent depending on time and current (periods of less than 10 seconds excluded).

De voedingsspanning van de elektrische aandrijving is afkomstig van een gelijkstroombron met een maximumspanningsverlies van 5 %, afhankelijk van het tijdstip en de stroom (perioden van minder dan 10 seconden niet inbegrepen).


The voltage drop between the main switchboard and the least favourable point of the installation shall not be more than 5 % for lighting or more than 7 % for power or heating circuits, referred to the nominal voltage.

Dit spanningsverlies, optredend tussen het hoofdschakelbord en het meest ongunstige punt van de installatie, mag bij verlichtingsinstallaties niet meer dan 5 % en voor kracht- en verwarmingsinstallaties niet meer dan 7 % van de nominale spanning bedragen.


- continue to work correctly or resume its correct functioning without loss of data available before the voltage drop if the voltage drop is temporary, i.e. due to restarting the engine;

- correct te blijven functioneren, of zijn correct functioneren te hervatten zonder verlies van de data die voor de spanningsdaling aanwezig waren, indien de spanningsdaling tijdelijk is, dat wil zeggen ten gevolge van het opnieuw starten van de motor;


continue to work correctly or resume its correct functioning without loss of data available before the voltage drop if the voltage drop is temporary, i.e. due to restarting the engine;

correct te blijven functioneren, of zijn correct functioneren te hervatten zonder verlies van de data die voor de spanningsdaling aanwezig waren, indien de spanningsdaling tijdelijk is, dat wil zeggen ten gevolge van het opnieuw starten van de motor;


abort an existing measurement and return to the position "For Hire" if the voltage drop is for a longer period.

een bestaande meting af te breken en naar de stand > terug te keren indien de spanningsdaling gedurende een langere periode optreedt.


w