Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Age-class interval
Age-class period
Class interval
Fire free interval
Fire interval
Fire return interval
Interval class
Interval training class
MFI
Mean fire interval
Mean fire-free interval
Mean fire-return interval
Size of class interval
VCI scale of rates
Value Class Interval
Value Class Interval scale of rates
Width of class interval

Traduction de «Class interval » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
size of class interval | width of class interval

amplitude de classe


age-class interval | age-class period

étendue d'une classe d'âges






Value Class Interval scale of rates [ VCI scale of rates ]

échelle des taux, par tranche de valeur






interval training class [ interval class ]

séance d'entraînement par intervalles


fire interval (1) | fire free interval (2) | fire return interval (3)

périodicité des incendies


mean fire interval | mean fire-free interval | mean fire-return interval [ MFI ]

périodicité moyenne des feux
TRADUCTIONS EN CONTEXTE
5. The verification scale interval for Class I and II weighing devices that are not equipped with auxiliary indicating elements, for Class III, IIIHD and IIII weighing devices, for multiple range devices and for multi-interval devices is equal to the actual scale interval.

5. Pour les appareils de pesage des classes I et II non munis d’un dispositif indicateur auxiliaire, les appareils de pesage des classes III, IIIHD et IIII, les appareils à étendues multiples et les appareils à échelons multiples, l’échelon de vérification est égal à l’échelon réel.


7. The verification scale interval for Class I and II weighing devices that are equipped with auxiliary indicating elements corresponds to the value of the scale interval preceding the actual scale interval of the auxiliary indicating element, and is larger than the actual scale interval.

7. Pour les appareils de pesage des classes I et II munis d’un dispositif indicateur auxiliaire, l’échelon de vérification correspond à la valeur de l’échelon précédant l’échelon réel du dispositif indicateur auxiliaire et est plus grand que l’échelon réel.


62 (1) A weighing device that is used in an application described in column 1 of the table to this section shall be from the accuracy class set out in column 2 for that device, or from a higher accuracy class, and shall be used to weigh a load that is not less than the amount obtained by multiplying the verification scale interval by the corresponding multiplying factor set out in column 3, and the device’s smallest verification scale interval shall not exceed that set out in column 4.

62 (1) L’appareil de pesage utilisé pour une application visée à la colonne 1 du tableau du présent article doit être de la classe de précision indiquée à la colonne 2 pour cet appareil ou d’une classe supérieure et servir à la pesée de charges au moins égales au produit de la multiplication de l’échelon de vérification par le facteur correspondant indiqué à la colonne 3, et son plus petit échelon de vérification ne peut dépasser celui indiqué à la colonne 4.


(3) The in-service limits of error that apply to a Class IIIHD weighing device are ±1 e where the load is not less than zero and not more than 500 verification scale intervals, and where the load exceeds 500 verification scale intervals, calculated by adding ±1 e for each additional 800 verification scale intervals or less, to a maximum of ±22 e.

(3) La marge de tolérance en service applicable à un appareil de pesage de la classe IIIHD est de ± 1 e pour toute charge comprise dans la tranche de 0 à 500 échelons de vérification et, pour toute charge excédant 500 échelons de vérification, s’accroît de ± 1 e, jusqu’à un maximum de ± 22 e, par tranche additionnelle de 800 échelons de vérification ou moins.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
6. For multi-interval devices, the verification scale interval of a particular partial weighing range must be smaller than the verification scale interval of the immediately superior partial weighing range, and each range must comply with the requirements set out in section 3 for the class into which the device falls.

6. Pour les appareils à échelons multiples, l’échelon de vérification d’une étendue de pesage partielle donnée doit être plus petit que celui de l’étendue de pesage partielle immédiatement supérieure, et chaque étendue doit satisfaire aux exigences de l’article 3 selon la classe d’appareil.


Instruments equipped with an auxiliary indicating device shall belong to class I or class II. For these instruments the minimum capacity lower limits for these two classes are obtained from Table 1 by replacement in column 3 of the verification scale interval (e) by the actual scale interval (d).

Les instruments équipés d'un dispositif indicateur auxiliaire appartiennent aux classes I ou II. Pour ces instruments, les limites minimales de portée pour ces deux classes sont tirées du tableau 1 par remplacement dans la colonne 3 de l'échelon de vérification (e) par l'échelon réel (d).


The relationship between the accuracy class and the scale interval shall be as specified in Table 10.

La relation entre la classe d'exactitude et l'échelon est celle indiquée dans le tableau 10.


6.2. The critical change value due to a disturbance shall be 0,7 times the appropriate value specified in Table 8, for a load equal to Σmin , for the designated class of the beltweigher; rounded up to the next higher totalisation scale interval (d).

6.2. La valeur de variation critique due à une perturbation doit être 0,7 fois la valeur appropriée indiquée dans le tableau 8, pour une charge égale à Σmin , pour la classe désignée de la peseuse sur bande, arrondie à l'échelon de totalisation (d) supérieur.


The relationship between the accuracy class and the scale interval shall be as specified in Table 10.

La relation entre la classe d'exactitude et l'échelon est celle indiquée dans le tableau 10.


6.2. The critical change value due to a disturbance shall be 0.7 times the appropriate value specified in Table 8, for a load equal to Σmin , for the designated class of the beltweigher; rounded up to the next higher totalisation scale interval (d).

6.2. La valeur de variation critique due à une perturbation doit être 0,7 fois la valeur appropriée indiquée dans le tableau 8, pour une charge égale à Σmin , pour la classe désignée de la peseuse sur bande, arrondie à l'échelon de totalisation (d) supérieur.




datacenter (1): www.wordscope.be (v4.0.br)

'Class interval' ->

Date index: 2022-08-14
w