Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
AST
Above ground storage tank
Above ground tank
Above-ground storage tank
Aboveground storage tank
Aerosol can air tank pressurized-gas tank
Air reservoir
Air tank
Air-brake reservoir
Air-brake storage tank
Compressed air tank
Fuel storage tank monitoring
Holding tank
Hot water tank
Hot-water storage tank
Hot-water tank
Low pressure storage tank
Manage storage tanks
Managing of storage tanks
Monitor fuel storage tanks
Monitoring diesel and gasoline storage tanks
Monitoring fuel storage tanks
Oversee storage tanks
Pressure storage tank
Sap feed tank
Sap holder
Sap storage tank
Storage bin
Storage drum
Storage reservoir
Storage tank
Storage tank management
Storage vat
Supply tank

Traduction de «Pressure storage tank » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
low pressure storage tank

réservoir de stockage sous basse pression




managing of storage tanks | oversee storage tanks | manage storage tanks | storage tank management

gérer des cuves de stockage


fuel storage tank monitoring | monitoring fuel storage tanks | monitor fuel storage tanks | monitoring diesel and gasoline storage tanks

surveiller des cuves de stockage de carburant


aboveground storage tank [ AST | above ground storage tank | above-ground storage tank | above ground tank ]

réservoir hors sol [ RHS | réservoir de stockage en surface | réservoir en surface | réservoir de stockage hors-sol | réservoir de surface ]


hot water tank [ hot-water tank | storage tank | storage bin | storage drum | hot-water storage tank ]

cuve de stockage [ ballon d'eau chaude | ballon réservoir | réservoir à eau chaude | réservoir de stockage d'eau chaude | réservoir d'eau chaude | réservoir de stockage ]


sap storage tank | holding tank | sap holder | storage vat | sap feed tank | supply tank | storage tank

réservoir d'emmagasinage | bassin d'entreposage


aerosol can air tank pressurized-gas tank

bombe aérosol réservoir de:air | gaz sous pression |


waste from transport and storage tank cleaning (except 05 00 00 and 12 00 00) | wastes from transport tank, storage tank and barrel cleaning (except 05 and 13)

déchets provenant du nettoyage des cuves de transport et de stockage(sauf catégories 05 00 00 et 12 00 00)


air-brake reservoir | air-brake storage tank | air reservoir | storage reservoir | air tank | compressed air tank

réservoir d'air comprimé | réservoir à air | réservoir d'air | réservoir de frein | bouteille d'air
TRADUCTIONS EN CONTEXTE
(e) American Petroleum Institute Standard 2000, Venting Atmospheric and Low-Pressure Storage Tanks.

e) la norme 2000 intitulée Venting Atmospheric and Low-Pressure Storage Tanks.


24 (1) Storage tanks shall be constructed in accordance with the 1956, 1959 or 1962 issue of the A.S.M.E. Boiler and Pressure Vessel Code for Unfired Pressure Vessels to a design working pressure not less than 125 per cent of the vapour pressure of the liquefied petroleum gas at 100°F, but not less than 250 psig for liquefied propane.

24 (1) Les réservoirs d’emmagasinage seront construits conformément aux prescriptions des éditions de 1956, 1959 ou 1962 du Code des chaudières et des récipients à pression de l’A.S.M.E. applicables aux récipients à pression non soumis à l’action du feu, de façon à pouvoir supporter une pression nominale de service qui soit d’au moins 125 pour cent de la tension de vapeur des gaz de pétrole liquéfiés à 100 °F, mais qui ne soit pas inférieure à 250 livres par pouce carré au manomètre dans le cas du propane liquéfié.


26. The storage tank shall be permanently marked or labelled as required by the A.S.M.E. Code under which the tank was manufactured and the Pressure Vessel Inspection Branch of the provincial government concerned.

26. Le réservoir d’emmagasinage portera en permanence la marque ou l’étiquette exigée par le code de l’A.S.M.E. selon lequel il a été fabriqué et par le service d’inspection des récipients à pression du gouvernement provincial en cause.


24 (1) All flammable liquid storage tanks shall be equipped with vent pipes or devices sized to keep the internal pressure or vacuum within the design limits of the tank.

24 (1) Tous les réservoirs d’emmagasinage de liquides inflammables seront munis de tuyaux d’évent ou de dispositifs de dimensions suffisantes pour maintenir la pression interne ou le vide dans les limites prévues pour le réservoir.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(b) a statement that the storage tank and vapourizer design shall be approved by the Pressure Vessel Inspection Branch of the provincial government concerned prior to fabrication of the tanks;

b) une déclaration mentionnant que l’étude des réservoirs d’emmagasinage et du vaporisateur sera approuvée par le service d’inspection des récipients à pression du gouvernement provincial en cause, avant la fabrication des réservoirs;


Content of the national legislation: Exemption from the requirements of 6.7 and 6.8 of the ADR for the carriage by road of nominally empty uncleaned storage tanks (for storage at fixed premises) for the purpose of cleaning, repair, testing or scrapping, provided that (a) as much of the pipe work which was connected to the tank as was reasonably practicable to remove from it has been removed; (b) a suitable pressure relief valve, which shall remain operational during the carriage, is fitted to the tank ...[+++]

Contenu de la législation nationale: exemption des prescriptions figurant sous 6.7 et 6.8 de l’ADR pour le transport par route de citernes fixes nominalement vides et non nettoyées (pour leur entreposage dans des lieux fixes) en vue de leur nettoyage, réparation, mise à l’essai ou mise à la ferraille, à condition que: a) tous les tuyaux fixés à la citerne qu’il est raisonnablement possible d’enlever aient été enlevés; b) la citerne ait été équipée d’un dispositif de décompression adéquat, qui doit rester opérationnel pendant le transport; et c), sous réserve du point b), to ...[+++]


Content of the national legislation: Exemption from the requirements of 6.7 and 6.8 of the ADR for the carriage by road of nominally empty uncleaned storage tanks (for storage at fixed premises) for the purpose of cleaning, repair, testing or scrapping, provided that (a) as much of the pipe work which was connected to the tank as was reasonably practicable to remove from it has been removed; (b) a suitable pressure relief valve, which shall remain operational during the carriage, is fitted to the tank ...[+++]

Contenu de la législation nationale: Exemption des prescriptions figurant sous 6.7 et 6.8 de l’ADR pour le transport par route de citernes fixes nominalement vides et non nettoyées (pour leur entreposage dans des lieux fixes) en vue de leur nettoyage, réparation, mise à l’essai ou mise à la ferraille, à condition que a) tous les tuyaux fixés à la citerne qu’il est raisonnablement possible d’enlever aient été enlevés; b) la citerne ait été équipée d’un dispositif de décompression adéquat, qui doit rester opérationnel pendant le transport; et c), sous réserve du point b), tou ...[+++]


Content of the national legislation: Exemption from the requirements of 6.7 and 6.8 of the ADR for the carriage by road of nominally empty uncleaned storage tanks (for storage at fixed premises) for the purpose of cleaning, repair, testing or scrapping, provided that (a) as much of the pipework which was connected to the tank as was reasonably practicable to remove from it has been removed; (b) a suitable pressure relief valve, which shall remain operational during the carriage, is fitted to the tank ...[+++]

Contenu de la législation nationale: exemption des prescriptions figurant sous 6.7 et 6.8 de l’ADR pour le transport par route de citernes fixes nominalement vides et non nettoyées (pour leur entreposage dans des lieux fixes) en vue de leur nettoyage, réparation, mise à l’essai ou mise à la ferraille, à condition que: a) tous les tuyaux fixés à la citerne qu’il est raisonnablement possible d’enlever aient été enlevés; b) la citerne ait été équipée d’un dispositif de décompression adéquat, qui doit rester opérationnel pendant le transport; et c), sous réserve du point b), to ...[+++]


Content of the national legislation: Exemption from the requirements of 6.7 and 6.8 of the ADR for the carriage by road of nominally empty uncleaned storage tanks (for storage at fixed premises) for the purpose of cleaning, repair, testing or scrapping, provided that (a) as much of the pipework which was connected to the tank as was reasonably practicable to remove from it has been removed; (b) a suitable pressure relief valve, which shall remain operational during the carriage, is fitted to the tank ...[+++]

Contenu de la législation nationale: exemption des prescriptions figurant sous 6.7 et 6.8 de l’ADR pour le transport par route de citernes fixes nominalement vides et non nettoyées (pour leur entreposage dans des lieux fixes) en vue de leur nettoyage, réparation, mise à l’essai ou mise à la ferraille, à condition que: a) tous les tuyaux fixés à la citerne qu’il est raisonnablement possible d’enlever aient été enlevés; b) la citerne ait été équipée d’un dispositif de décompression adéquat, qui doit rester opérationnel pendant le transport; et c), sous réserve du point b), to ...[+++]


Content of the national legislation: [Proposed] Exemption from the requirements of Chapters 6.7. and 6.8. of the ADR for the carriage by road of nominally empty uncleaned storage tanks (for storage at fixed premises) for the purpose of cleaning, repair, testing or scrapping; provided (a) as much of the pipe work which was connected to the tank as it was reasonably practicable to remove from it has been removed; (b) a suitable pressure relief valve, which shall remain operational during the c ...[+++]

Contenu de la législation nationale: exemption [proposée] des prescriptions des chapitres 6.7 et 6.8 de l'ADR pour le transport par route de citernes fixes nominalement vides et non nettoyées en vue de leur nettoyage, réparation ou mise à la ferraille, à condition que a) tous les tuyaux fixés à la citerne qu'il est raisonnablement possible d'enlever aient été enlevés, b) la citerne ait été équipée d'un dispositif de décompression adéquat, qui doit rester opérationnel pendant le transport, et c) toutes les ouvertures dans la citerne et dans ...[+++]


w