Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Boric acid emergency shutdown system
Communicate using emergency communication tools
EFS
Emergency floatation gear
Emergency floatation system
Emergency flotation equipment
Emergency flotation gear
Emergency flotation system
Emergency scram
Emergency shutdown
Emergency shutdown and cooling system
Emergency shutdown system
Guarantee facility security equipment
Maintain facility emergency and security systems
Maintain facility security systems
Maintain security systems at the facility
Operate an emergency communication system
Operate communication system used in emergencies
Operate emergency communication system
Rapid shutdown
Safety shutdown system
Scram

Traduction de «emergency shutdown system » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
emergency shutdown system | safety shutdown system

système d'arrêt d'urgence | système d'arrêt de sécurité


boric acid emergency shutdown system

dispositif d'arrêt d'urgence à l'acide borique


emergency shutdown | rapid shutdown | scram

arrêt d'urgence




communicate using emergency communication tools | operate emergency communication system | operate an emergency communication system | operate communication system used in emergencies

faire fonctionner un système de communication d’urgence


emergency shutdown and cooling system

système d'arrêt et de refroidissement d'ultime secours


emergency flotation system [ EFS | emergency floatation system | emergency flotation gear | emergency floatation gear | emergency flotation equipment ]

dispositif de flottaison d'urgence [ DFU | système de flottabilité de secours | système de flottaison d’urgence ]


emergency shutdown | scram

arrêt d'urgence du réacteur | arrêt d'urgence | AU




guarantee facility security equipment | maintain security systems at the facility | maintain facility emergency and security systems | maintain facility security systems

entretenir les systèmes de sécurité d'installations
TRADUCTIONS EN CONTEXTE
(6) The emergency shutdown system shall be designed to permit the selective shutdown of the ventilation systems required by section 10, except the fans necessary for supplying combustion air to prime movers for the production of electrical power.

(6) Le système d’arrêt d’urgence doit être conçu pour permettre l’arrêt sélectif des systèmes de ventilation visés à l’article 10, sauf les ventilateurs nécessaires à l’admission de l’air de combustion des moteurs primaires servant à la production d’énergie électrique.


(9) The emergency shutdown system shall be connected to a source of power in such a way that, in the event of a failure of the primary source of power, there is automatic changeover to an emergency source of power and audible and visual alarms indicating that failure are given at the appropriate control point.

(9) Le système d’arrêt d’urgence doit être branché à une source d’énergie électrique de sorte qu’en cas de défaillance de la source d’énergie primaire, le passage à la source de secours soit automatique et des alarmes sonores et visuelles indiquant cette défaillance soient déclenchées au poste de commande approprié.


(8) After an emergency shutdown, the emergency shutdown system shall stay in a locked-out condition until it is manually reset.

(8) Après un arrêt d’urgence, le système d’arrêt d’urgence doit demeurer verrouillé jusqu’à ce qu’il soit remis en marche manuellement.


(4) In the case of a production installation, manual operation of an emergency shutdown system shall be in accordance with American Petroleum Institute RP 14C, Recommended Practice for Analysis, Design, Installation and Testing of Basic Surface Safety Systems for Offshore Production Platforms.

(4) Dans le cas de l’installation de production, le fonctionnement manuel du système d’arrêt d’urgence doit être conforme au document RP 14C de l’American Petroleum Institute intitulé Recommended Practice for Analysis, Design, Installation and Testing of Basic Surface Safety Systems for Offshore Production Platforms.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
1.6.2. When the emergency shutdown system is actuated, accumulated energy must be dispersed as quickly and as safely as possible or isolated so that it no longer constitutes a hazard.

1.6.2. Les énergies emmagasinées doivent être dissipées aussi vite et sûrement que possible ou isolées lorsqu'on actionne les dispositifs de coupure d'urgence, de façon à ce qu'elles ne soient plus une source de danger.


1.6.2. When the emergency shutdown system is actuated, accumulated energy must be dispersed as quickly and as safely as possible or isolated so that it no longer constitutes a hazard.

1.6.2. Les énergies emmagasinées doivent être dissipées aussi vite et sûrement que possible ou isolées lorsqu’on actionne les dispositifs de coupure d’urgence, de façon à ce qu’elles ne soient plus une source de danger.


A. whereas the recent earthquake with thousands of victims in North-Eastern Japan led to the shutdown of a number of Japan's operational nuclear reactors and whereas the following tsunami with tidal waves higher than 10 meters destroyed not only the existing power grids but also the backup and emergency supply systems of the Fukushima Daiichi nuclear power plant; whereas the resulting lack of cooling capacity led to overheating of some of the nuclear fuel elements and to a meltdown of parts the core reactor; whereas so far the IAEA ...[+++]

A. considérant que le tremblement de terre qui a fait récemment des milliers de victimes dans le nord-est du Japon a entraîné la fermeture de plusieurs réacteurs nucléaires fonctionnant au Japon, et considérant que le tsunami qui a suivi, avec des vagues hautes de plus de 10 mètres, a détruit non seulement les réseaux électriques existants, mais également les systèmes de secours et d'approvisionnement d'urgence de la centrale nucléaire de Fukushima Daiichi; considérant que l'absence de possibilité de refroidissement qui en a découlé a entraîné la surchauffe de certains des é ...[+++]


3.2. Equipment capable of remote control as referred to in point 3.1 must at least include systems for ventilation, emergency shutdown of equipment which could give rise to ignition, the prevention of the escape of flammable liquids and gas, fire protection and well control.

3.2. Les équipements pouvant faire l'objet d'une commande à distance visée au point 3.1 doivent au moins comprendre des systèmes de ventilation, des dispositifs d'arrêt d'urgence d'équipements susceptibles de provoquer des inflammations, un système de prévention des fuites de liquides et de gaz inflammables ainsi que des systèmes de protection contre l'incendie et de contrôle des puits.


The most contentious of the planned improvements is the upgrade to the emergency shutdown system.

La modernisation du système d’arrêt d’urgence constitue la plus controversée des améliorations prévues.


w