Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Engine operating temperature
Extreme operating temperature
Maximum continuous operating temperature
Maximum operating temperature
Maximum service temperature
Maximum working temperature
Minimum operating temperature
Minimum service temperature
Minimum working temperature
Non operating temperature range
Operating temperature
Operative temperature
Service temperature
Survival temperature range
Working temperature

Traduction de «operating temperature » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
operating temperature | service temperature | working temperature

température de service | température de fonctionnement | température d'utilisation


maximum operating temperature | maximum service temperature | maximum working temperature

température maximale en service


non operating temperature range [ survival temperature range ]

plage de température hors service survie




engine operating temperature

température de marche du réacteur


extreme operating temperature

température extrême d'utilisation




minimum working temperature | minimum operating temperature | minimum service temperature

température minimale en service | TBS


maximum continuous operating temperature

température maximale en régime continu


TRADUCTIONS EN CONTEXTE
4.1.1. Using the applicable bench cycle and ageing bench hardware, age several catalysts (minimum of 3 of the same catalyst design) at different control temperatures between the normal operating temperature and the damage limit temperature.

4.1.1. Utiliser le cycle et l’équipement de banc de vieillissement qui conviennent, vieillir plusieurs catalyseurs (au moins trois du même type) à différentes températures de contrôle entre la température normale de fonctionnement et la température de limite d’endommagement.


Unless other values are required in accordance with other criteria that shall be taken into account, a steel is considered as sufficiently ductile to satisfy point 4.1(a) if, in a tensile test carried out by a standard procedure, its elongation after rupture is no less than 14 % and its bending rupture energy measured on an ISO V test-piece is no less than 27 J, at a temperature not greater than 20 °C but not higher than the lowest scheduled operating temperature.

À moins que d'autres valeurs ne soient requises au titre d'autres critères qui doivent être pris en compte, un acier est considéré comme suffisamment ductile pour satisfaire au point 4.1 a) si son allongement après rupture dans un test de traction réalisé selon une procédure standard est au moins égal à 14 % et si son énergie de flexion par choc sur éprouvette ISO V est au moins égale à 27 J, à une température au plus égale à 20 °C, mais non supérieure à la plus basse température de fonctionnement prévue.


(i) Engine shall be fully warm, for instance the engine oil temperature measured by a probe in the oil level dipstick tube to be at least 80 ºC, or normal operating temperature if lower, or the engine block temperature measured by the level of infrared radiation to be at least an equivalent temperature.

(i) Le moteur doit être chaud: autrement dit, la température de l'huile moteur mesurée par une sonde dans le tube de la jauge doit au moins être égale à 80 °C ou correspondre à la température de fonctionnement normale si celle-ci est inférieure, ou la température du bloc-moteur, mesurée d'après le niveau du rayonnement infrarouge, doit atteindre une valeur au moins équivalente.


(i) Engine shall be fully warm, for instance the engine oil temperature measured by a probe in the oil level dipstick tube to be at least 80 ºC, or normal operating temperature if lower, or the engine block temperature measured by the level of infrared radiation to be at least an equivalent temperature.

(i) Le moteur doit être chaud: autrement dit, la température de l'huile moteur mesurée par une sonde dans le tube de la jauge doit au moins être égale à 80 °C ou correspondre à la température de fonctionnement normale si celle-ci est inférieure, ou la température du bloc-moteur, mesurée d'après le niveau du rayonnement infrarouge, doit atteindre une valeur au moins équivalente.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
‘multi-use compartment’ means a compartment intended for use at two or more of the temperatures of the compartment types and capable of being set by the end-user to continuously maintain the operating temperature range applicable to each compartment type according to the manufacturer’s instructions; however, where a feature can shift temperatures in a compartment to a different operating temperature range for a period of limited duration only (such as a fast-freeze facility), the compartment is not a ‘multi-use compartment’ as defined by this Regulation.

«compartiment polyvalent», un compartiment qui peut être utilisé à deux ou plusieurs des températures correspondant aux différents types de compartiments et que l’utilisateur final peut régler afin de maintenir en permanence l’échelle des températures de fonctionnement applicables à chaque type de compartiment conformément aux instructions du fabricant; cependant, lorsqu’un dispositif peut faire varier les températures dans un compartiment selon une échelle de températures de fonctionnement différentes pour une période limitée uniquement (tel qu’un système de congélation rapide), le compartiment n’est pas considéré comme un «compartimen ...[+++]


In order to prove this, the hydrogen components are submitted to a temperature cycle of specified duration from the minimum operating temperature up to the maximum operating temperature.

Pour ce faire, les composants hydrogène sont soumis à un cycle de température d’une durée spécifiée allant de la température de service la plus basse à la température de service la plus élevée.


Within its territory each Member State in which the ambient temperature is regularly lower than – 20 °C may impose more stringent standards as regards the operating temperature of materials used for plastic packaging, tanks and their equipment intended for use in the national transport of dangerous goods by road until provisions on the appropriate reference temperatures for given climatic zones are incorporated into Annex I, Section I. 1, to this Directive.

Les États membres où la température ambiante est régulièrement inférieure à – 20 °C peuvent imposer sur leur territoire des normes plus strictes en matière de température d’utilisation des matériaux utilisés pour les emballages plastiques, les citernes et leurs équipements destinés au transport national de marchandises dangereuses par route, jusqu’à ce que des dispositions relatives aux températures de référence appropriées pour des zones climatiques déterminées soient incorporées dans l’annexe I, section I. 1, de la présente directive.


Within its territory each Member State in which the ambient temperature is regularly lower than – 20 °C may impose more stringent standards as regards the operating temperature of materials used for plastic packaging, tanks and their equipment intended for use in the national transport of dangerous goods by rail until provisions on the appropriate reference temperatures for given climatic zones are incorporated into Annex II, Section II. 1, to this Directive.

Les États membres où la température ambiante est régulièrement inférieure à – 20 °C peuvent imposer sur leur territoire des normes plus strictes en matière de température d’utilisation des matériaux utilisés pour les emballages plastiques, les citernes et leurs équipements destinés au transport national de marchandises dangereuses par chemin de fer, jusqu’à ce que des dispositions relatives aux températures de référence appropriées pour des zones climatiques déterminées soient incorporées dans l’annexe II, section II. 1, de la présente directive.


The gas mixture temperature immediately ahead of the PDP shall be within ± 6 K of the average operating temperature observed during the test, when no flow compensation is used.

La température du mélange gazeux immédiatement en amont du PDP doit être maintenue à ± 6 K de la température moyenne de fonctionnement observée au cours de l'essai, sans compensation du débit.


The heat exchanger shall be of sufficient capacity to maintain the temperature at the inlet to the suction blower SB within ± 11 K of the average operating temperature observed during the test.

L'échangeur de chaleur doit être d'une capacité suffisante pour maintenir la température à l'entrée de l'aspirateur SB à ± 11 K de la température de fonctionnement moyenne observée pendant l'essai.


w